Powerful Vertiv Liebert EXS 40kVA: Ultimate Protection!

Mid-to-large facilities running dense, business-critical infrastructure need power protection that scales without an oversized footprint. The Vertiv Liebert EXS ITC401A0101A00A offers 40kVA of true double-conversion online protection in a 0-minute autonomy configuration. It’s built for facilities that integrate the UPS with external battery cabinets instead of relying on internal battery capacity alone.

Introducing the ITC401A0101A00A

The ITC401A0101A00A is a mid-tier model in Vertiv’s Liebert EXS series, an optimized and integrated three-phase UPS platform engineered for high-efficiency power protection. At 40kVA, it fits facilities with substantial needs that sit between smaller server room deployments and full enterprise-scale infrastructure. It delivers a large amount of active power within a compact footprint.

0-Minute Autonomy Configuration of the ITC401A0101A00A

Instead of shipping with a fixed internal battery bank, the ITC401A0101A00A is configured for 0-minute autonomy and designed to work with external battery cabinets or existing facility backup systems. Data centers and industrial sites can size runtime independently of the UPS chassis. They avoid spending space and money on internal batteries when a custom-scaled external solution suits their needs better.

Double-Conversion Efficiency Up to 96.2% in the ITC401A0101A00A

A standout strength of the ITC401A0101A00A is its double-conversion efficiency of up to 96.2%, strong for online UPS technology. ECO mode efficiency can reach up to 99%. Facilities get the full benefit of true online protection, continuous voltage regulation and zero transfer time, without the steep energy overhead older double-conversion designs carried.

Compact Design and Reduced Footprint: The ITC401A0101A00A

The Liebert EXS platform behind the ITC401A0101A00A is built around a compact design philosophy. It keeps the physical footprint small while still delivering serious active power. That matters where floor space carries real cost, because 40kVA of protection can go in without the disproportionate footprint older three-phase UPS systems often required.

Output Power Factor and Clean Power Delivery on the ITC401A0101A00A

The ITC401A0101A00A offers an output power factor of up to 1, so its full rated capacity becomes usable active power for connected equipment. Input current total harmonic distortion (THDi) correction delivers clean power to protected loads and limits the electrical noise the UPS sends back into the facility’s upstream power infrastructure.

Integrated Manual Bypass and Breaker Protection on the ITC401A0101A00A

Built-in safeguards include integrated manual bypass along with integrated input and output breakers and switches. These simplify maintenance and give facility teams a reliable way to handle fault conditions or service the unit without leaving connected equipment exposed.

Parallel Capability of the ITC401A0101A00A

With an integrated parallel load bus and synchronization port (LBS), the ITC401A0101A00A supports parallel configuration with additional compatible units. Facilities can add capacity or introduce genuine redundancy as they grow, which protects the long-term value of their initial Liebert EXS investment.

Who Should Choose the ITC401A0101A00A

The ITC401A0101A00A suits data centers, server rooms, and industrial facilities that need substantial 40kVA protection and the flexibility to design their own external battery runtime strategy. It’s especially valuable for organizations standardizing on external battery infrastructure or planning future parallel expansion.

Final Thoughts on the ITC401A0101A00A

For facilities that need serious mid-to-large-scale power protection without an oversized physical or energy footprint, the Vertiv Liebert EXS ITC401A0101A00A combines double-conversion reliability, high efficiency, and real runtime flexibility. Parallel capability, integrated bypass protection, and a scalable approach to battery infrastructure make it a smart choice for facilities investing in 40kVA three-phase power protection.

CONTACT US @ TIACO TECHNOLOGIES.

Right-Sized, High-Efficiency Protection: The Vertiv ITC401A0101A00A

At 40kVA, a UPS is protecting real, substantial infrastructure — data center racks, large server rooms, and demanding commercial equipment loads. The Vertiv Liebert EXS ITC401A0101A00A delivers that level of protection while staying true to the EXS line’s defining trait: genuinely compact, transformer-free design that doesn’t sacrifice efficiency for footprint.

What the Vertiv ITC401A0101A00A Delivers

Liebert EXS combines compact design and improved performances. It is able to provide the utmost active power possible in a compact footprint. In fact, its improved design reduces its footprint to a minimum and enhances its double conversion efficiency up to 96.2%, providing continuous power protection with optimised internal runtime in a standalone solution. At 40kVA, the unit delivers substantial three-phase capacity built specifically for data centers, large server rooms, and commercial facilities.

Efficiency Behind the Vertiv ITC401A0101A00A

Double conversion efficiency reaches up to 96.2%, with ECO mode efficiency climbing as high as 99% — genuinely leading-edge figures for a UPS at this capacity tier. High efficiency operation reduces energy costs and heat, meaning the ITC401A0101A00A doesn’t just protect your equipment, it does so while meaningfully lowering the operating cost and cooling burden that comes with running 40kVA of continuous power conversion.

A 0-Minute Autonomy Configuration

This particular ITC401A0101A00A configuration ships with 0 minutes of integrated battery autonomy — engineered specifically for facilities that already have an external battery cabinet, dedicated DC power infrastructure, or generator backup in place. Rather than paying for internal battery capacity that duplicates existing infrastructure, this configuration lets you architect your runtime strategy exactly the way your facility’s actual power protection plan requires.

Reduced Total Cost of Ownership

The Liebert EXS platform is built around a genuinely comprehensive set of cost- and space-saving design principles: reduced total cost of ownership, a compact footprint, multiple internal runtime configurations, high power density, installation flexibility, integrated maintenance bypass, and integrated input and output power distribution. Dual mains input is also included, giving the unit the ability to draw from two separate power sources for genuine redundancy at this critical capacity tier.

Integrated Maintenance Bypass Keeps Loads Running

Even mission-critical infrastructure needs periodic service, and the ITC401A0101A00A is designed so that maintenance never becomes a source of downtime. Its integrated maintenance bypass ensures connected critical loads keep operating even during scheduled service work — a genuinely important feature for data centers and server rooms where any unplanned interruption carries real cost.

Parallel Capability for Growing Infrastructure

Parallel capability for capacity and redundancy means the Vertiv ITC401A0101A00A isn’t a fixed ceiling on your infrastructure’s power protection. Liebert EXS can be connected with up to four units in parallel, and a single unit can be upgraded to parallel operation via easy to modify software settings — a genuine, cost-effective path to scaling total capacity or adding real redundancy as your organization’s requirements grow, without a full infrastructure overhaul.

Advanced Diagnostics and Monitoring

Advanced diagnostics help monitor UPS health and status, giving IT and facilities teams genuine visibility into the unit’s condition rather than waiting for a failure to reveal a developing problem. That kind of proactive insight matters enormously for infrastructure supporting data centers and enterprise environments, where catching a degrading component early can prevent a much larger, costlier failure down the line.

Flexible Installation for Enterprise Environments

Flexible installation makes the ITC401A0101A00A suitable for data centers and enterprise environments of varying layouts, while common or distributed battery bank configurations and internal or external battery options give facilities teams real flexibility in how they architect their overall runtime and redundancy strategy around the unit.

Backed by Global Vertiv Support

Vertiv offers a complete range of services specifically designed for three-phase UPS systems, with coverage options extending up to 5 years and backed by a global network spanning more than 270 service centers and 2,700 field engineers across more than 130 countries — genuine, dependable support behind a UPS this central to your infrastructure.

The Bottom Line on the Vertiv ITC401A0101A00A

For data centers, large server rooms, and commercial facilities running genuinely substantial 40kVA loads, the Vertiv Liebert EXS ITC401A0101A00A delivers real double-conversion efficiency up to 96.2%, integrated maintenance bypass, dual mains input, and parallel scalability up to four units — all in a 0-minute autonomy configuration built for facilities with their battery and generator architecture already planned. It’s compact, high-efficiency power protection engineered for the infrastructure that genuinely can’t afford compromise.

CONTACT US @ TIACO TECHNOLOGIES.