A Comprehensive Look at the APC Switched Rack PDU AP7922B

In the high-stakes world of IT infrastructure, where servers hum 24/7 and downtime can cost thousands per minute, power management isn’t just a nice-to-have—it’s mission-critical. Enter the APC Switched Rack PDU AP7922B, a 2U powerhouse designed to deliver precise control over power distribution in your rack environment. Tailored for 230V setups with a robust 32A capacity, this unit features 16 C13 outlets and advanced switching capabilities, making it ideal for data centers, server rooms, or enterprise edge computing. As part of APC’s (Schneider Electric) renowned NetShelter lineup, the AP7922B combines reliability with smart monitoring to keep your operations running smoothly. Let’s break down what makes this PDU a game-changer.

Key Features That Drive Efficiency

The AP7922B stands out for its blend of rugged hardware and intelligent software, empowering IT admins with tools to optimize power usage and prevent issues before they escalate. Here’s a spotlight on its standout capabilities:

  • Outlet-Level Switching: Remotely turn individual outlets on or off via Ethernet—perfect for rebooting stubborn servers without physical access or sequencing power-ups to avoid inrush currents.
  • Real-Time Power Monitoring: Track current, voltage, and power draw at the outlet level, with user-defined alarms for thresholds like overloads or underutilization.
  • Power Sequencing: Automatically stagger outlet activation to protect equipment from damaging surges during startup, a boon for dense rack configurations.
  • Temperature/Humidity Sensor Port: Connect APC’s environmental sensors for holistic monitoring, helping maintain optimal conditions in your enclosure.
  • Locking IEC Receptacles: Secure C13 outlets prevent accidental unplugging, ensuring uptime in vibration-prone environments.
  • Compact 2U Design: Fits seamlessly into standard 19-inch racks, with a 10-foot cord for flexible installation and horizontal/vertical mounting options.

These features adhere to industry standards, including UL and IEC certifications, ensuring compatibility and safety in global deployments.

Technical Specifications at a Glance

For those diving deeper, the AP7922B’s specs reflect APC’s engineering prowess. We’ve compiled them into this easy-reference table:

SpecificationDetails
ModelAPC AP7922B (AP8000 Series)
Form Factor2U Rack-Mountable
Input Voltage200V / 208V / 230V AC
Input Current32A
Input ConnectorIEC 309 32A (2P+E)
Output Voltage230V AC
Output Outlets16 x IEC C13
Cord Length10 feet (3m)
Dimensions (H x W x D)89 mm x 445 mm x 114 mm
Weight4.5 kg
Management InterfaceEthernet 10/100BaseT
Operating TemperatureUp to 60°C at full load (hybrid outlets)
CertificationsUL, IEC, RoHS

This setup supports a maximum load of around 7.36 kW, making it suitable for mid-sized racks without overwhelming your circuit.

The Real-World Benefits: Control, Uptime, and Savings

Imagine a midnight alert: a server in your remote colo facility is unresponsive. With the AP7922B, you log into its web interface from your phone, cycle the outlet, and it’s back online—no frantic calls to on-site techs. This remote control slashes mean time to repair (MTTR) and reduces travel costs, especially in distributed setups.

For energy-conscious ops, the monitoring tools help identify power hogs, enabling load balancing that can cut electricity bills by 10-20% in optimized environments. The fail-safe design, including overload protection and auto-disconnect, guards against costly hardware failures. Plus, its eco-friendly build (RoHS compliant) aligns with green IT goals, minimizing e-waste.

In high-density scenarios, like edge computing or virtualization farms, the sequencing prevents the “big bang” overload from simultaneous boots, extending equipment life. Overall, it’s a scalable solution that grows with your infrastructure.

What Users Are Saying

Feedback on the AP7922B highlights its reliability in demanding setups. On Amazon, it holds strong ratings for build quality and ease of integration, with users noting the “intuitive web UI for quick reboots.” Data center pros praise the remote management, calling it “a lifesaver for high-demand environments” where downtime is non-negotiable. One reviewer appreciated the locking outlets: “No more loose plugs in our vibrating racks—solid uptime boost.” Common pros include robust monitoring and sequencing; a minor con is the lack of built-in Wi-Fi (Ethernet only). With an average of 4.5+ stars across sites, it’s a trusted pick for pros.

Final Thoughts: Secure Your Power, Secure Your Future

The APC AP7922B isn’t just a PDU—it’s a smart guardian for your rack’s power ecosystem, blending switched control with precise monitoring to deliver unmatched efficiency and peace of mind. It’s an investment that pays off in reduced downtime and smarter resource use, especially for 230V international deployments.

Whether you’re outfitting a new data center or upgrading legacy gear, this 2U switched unit from APC’s AP8000 series is worth the rack space. CONTACT US @ TIACO TECHNOLOGIES – your servers will run cooler and longer.

The APC Switched Rack PDU AP7922B

In the high-stakes world of data centers and server rooms, precise power distribution and remote management are key to maintaining uptime and efficiency. The APC Switched Rack PDU AP7922B, a 2U horizontal unit from Schneider Electric, delivers exactly that—offering 32A at 230V with 16 IEC C13 outlets for seamless power delivery to rack-mounted equipment. Designed for single-phase setups, this metered and switched PDU enables IT admins to monitor loads in real-time, cycle power remotely, and prevent overloads, all while integrating effortlessly into existing networks. Whether you’re optimizing a colocation facility or fortifying an enterprise server rack, the AP7922B combines robust performance with user-friendly controls to future-proof your power strategy.

Key Features That Drive Efficiency

The AP7922B stands out with its blend of hardware reliability and software intelligence, making power management intuitive and proactive. Standout elements include:

  • Outlet-Level Switching: Remotely turn outlets on/off individually to reboot devices, restrict access, or sequence power-up for safe startups—ideal for troubleshooting without on-site visits.
  • Real-Time Monitoring: Tracks current, voltage, and power metrics per outlet and overall, with customizable thresholds for alerts on potential issues.
  • Secure Network Interfaces: Supports Web, SNMP, Telnet, and CLI for configuration, plus integration with APC’s StruxureWare platforms like Data Center Expert for centralized oversight.
  • Wide Input/Output Flexibility: Handles 220-240V inputs and outputs 230V AC, with a 3.05m cable and IEC 60309 input plug for easy installation in global setups.
  • Durable Rack Design: 2U form factor with front-to-rear airflow compatibility, ensuring it fits standard 19-inch racks without compromising cooling.
  • Advanced Protocols and Security: Features user authentication, event logging, and firmware upgradability to keep your infrastructure secure and current.

These capabilities transform the AP7922B from a simple power strip into a smart tool for dynamic IT environments.

Technical Specifications at a Glance

Here’s a compiled overview of the AP7922B’s core specifications, based on official product data:

CategoryDetails
Power Rating32A, 7360 VA (single-phase)
Input Voltage200V / 208V / 230V (220-240V adjustable)
Output Voltage230V AC
Frequency50/60 Hz
Outlets16 x IEC 320 C13
Input ConnectionIEC 60309 309 plug
Cable Length3.05 m
Dimensions (H x W x D)89 mm x 445 mm x 114 mm (3.5″ x 17.5″ x 4.5″)
Weight4.5 kg (net)
Rack Units2U horizontal
Operating Temperature0–45°C; Humidity: 0–95% non-condensing
CertificationsCE, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, REACH
Management ProtocolsHTTP/HTTPS, SNMP v1/v3, Telnet, SSH, CLI
Warranty1 year (repair or replace)

This PDU supports up to 14.4kW in similar APC families, but the AP7922B’s 7.36kVA rating suits mid-sized racks perfectly.

Benefits and Ideal Use Cases

The AP7922B shines by reducing operational overhead—remote controls cut travel time for reboots, while metering helps optimize energy use and avoid spikes that could trip breakers. Its switched functionality supports power-on sequencing to protect hardware during startups, and integration with EcoStruxure IT enables predictive maintenance. As a RoHS-compliant unit, it aligns with green initiatives, it delivers strong ROI through minimized downtime.

It’s tailored for:

  • Data Centers: Monitors and manages dense server clusters with per-outlet granularity.
  • Enterprise IT Rooms: Enables remote power cycling for distributed teams handling edge computing.
  • Colocation Facilities: Provides secure, auditable access controls for multi-tenant environments.
  • Network Cabinets: Distributes power to switches and storage in telecom or financial setups.

IT pros value its intuitive web interface for quick setups and reliable performance under load.

Wrapping Up: Precision Power for Demanding Racks

The APC Switched Rack PDU AP7922B is a powerhouse of control and insight, empowering IT teams to handle power like never before. With its 2U efficiency, 16 switched outlets, and robust monitoring, it’s a must-have for any rack demanding reliability and remote smarts. Elevate your infrastructure today—CONTACT US @ TIACO TECHNOLOGIES for availability and accessories.

APC Switched Rack PDU AP7922B

In the dense, high-stakes world of data centers and server rooms, where every watt counts and downtime is measured in dollars, intelligent power distribution is the unsung hero of efficiency. The APC Switched Rack PDU AP7922B—a 2U, 32A, 230V unit with 16 C13 outlets—delivers precisely that: switched, metered control over power delivery to your rack-mounted gear. From Schneider Electric’s robust APC NetShelter lineup, this PDU empowers IT admins to remotely cycle outlets, monitor loads in real-time, and sequence power-ups to prevent inrush overloads. As we roll through September 2025 with escalating demands on edge computing and AI workloads, the AP7922B remains a cornerstone for scalable, secure power management. In this blog, we’ll unpack its specs, standout features, deployment tips, and why it’s a favorite among data center pros.

What Is the APC AP7922B Switched Rack PDU?

The AP7922B is a horizontal, rack-mountable Switched Rack PDU designed for single-phase 230V environments, distributing up to 7360VA of power across 16 IEC C13 outlets. It features an integrated current sensor for per-phase metering and individual outlet switching, allowing granular control over connected devices like servers, switches, and storage arrays. Input comes via a durable IEC 60309 32A plug on a 3.05m cord, making it plug-and-play for standard European racks.

It includes mounting hardware, a network cable, and access to APC’s EcoStruxure IT for centralized oversight. With a 1-year warranty and flash-upgradeable firmware, it’s built for longevity in 19-inch racks, occupying just 2U of vertical space. This PDU shines in mid-sized setups, bridging basic PDUs and full enterprise metered units.

Key Features and Specifications

The AP7922B combines robust hardware with smart networking for proactive power governance. Here’s a snapshot of its core specs:

FeatureDescriptionBenefit
Capacity & Input7360VA max; 32A single-phase; IEC 60309 32A input plug; 3.05m cordHandles high-density loads up to 230V without derating; Flexible for global 200-230V grids.
Output16x IEC C13 outlets; 230V ACPowers standard IT equipment; Switched control per outlet for targeted on/off.
Metering & SwitchingPer-phase current monitoring; Outlet-level switchingReal-time load tracking via web/SNMP; Remote rebooting without physical access.
Management InterfacesEthernet 10/100; Web, SNMP, Telnet, SSH; StruxureWare integrationSecure remote config; Firmware upgrades over network for future-proofing.
Physical Specs2U horizontal; 444 x 114 x 203 mm (W x H x D); ~8kg; Black metal housingFits standard 19″ racks; Compact for dense deployments with passive cooling.
Safety & AlarmsOverload thresholds; Network/visual alerts; Power delays/sequencingPrevents circuit trips; Email/SNMP notifications for proactive issue resolution.
CertificationsIEC 62040-2; CE; RoHSGlobal compliance for safe, eco-friendly operation in regulated environments.

These elements make it a versatile choice, with up to 98% efficiency in bypass modes and support for up to four PDUs on a single network drop via port sharing.

Why Choose the AP7922B? Benefits for Your Data Center

In 2025’s power-constrained landscapes, the AP7922B elevates rack management from reactive to strategic:

  • Granular Remote Control: Switch individual outlets via web or CLI to reboot hung servers or schedule maintenance, slashing MTTR in distributed teams.
  • Load Optimization: Real-time metering and alarm thresholds spot imbalances early, avoiding overloads and enabling capacity planning for growing AI/ML clusters.
  • Sequenced Power Management: Programmable delays prevent startup surges, protecting circuits and extending hardware life—ideal for hot-swappable environments.
  • Seamless Integration: Ties into EcoStruxure for holistic DCIM, supporting SNMPv3 for secure, standards-based oversight without added costs.

Admins report up to 30% better utilization in racks, turning power from a bottleneck into a boon for efficiency and sustainability.

Installation: A Streamlined Guide

The AP7922B’s rack-ready design simplifies deployment, often in under 30 minutes. Always follow APC’s manual, but here’s the essentials (engage a qualified electrician for hardwiring if needed):

  1. Rack Prep: Secure 2U space in a 19″ enclosure with adequate airflow. Verify 230V/32A feed availability.
  2. Mount the PDU: Use included rails or brackets to install horizontally. Connect the IEC 60309 plug to your upstream source (e.g., UPS or panel).
  3. Cable Up: Plug devices into C13 outlets, grouping critical loads. Attach Ethernet for management—default IP via DHCP.
  4. Configure Access: Log in via web (user: apc, pass: apc), set thresholds, and enable SNMP. Test switching and metering with a load simulator.
  5. Integrate & Test: Link to StruxureWare if using; Run a full self-test for alarms. Pro tip: Sequence outlets for boot order to mimic production.

APC’s online guides and videos cover edge cases like firmware flashes.

Real-User Insights: What Data Center Pros Are Saying

The AP7922B scores high for reliability, with eBay and reseller averages around 4.5/5 from enterprise buyers. One FaithJCom reviewer gave it 5/5: “With industry-leading reliability… advanced load management plus on/off outlet level power cycling,” praising its role in secure remote ops. On Comms Express, users highlight integration: “Full-featured network management… save valuable time,” noting seamless StruxureWare ties.

Is the AP7922B Right for You? Final Thoughts

For IT teams managing 5-20kW racks in 230V setups, the APC Switched Rack PDU AP7922B is a powerhouse of control and insight—delivering switched precision without the complexity of higher-end models. Its metering smarts, remote accessibility, and APC ecosystem make it indispensable for efficient, resilient infrastructure amid rising power demands.

CONTACT US @ TIACO TECHNOLOGIES for bundles with sensors. Powered your rack with one? Share your load stories in the comments!

APC Switched Rack PDU AP7922B

In the high-stakes world of data centers and server rooms, reliable power distribution is the backbone of uninterrupted operations. As demands for efficiency, remote management, and scalability grow in 2025, switched PDUs like the APC Rack PDU, Switched, 2U, 32A, 230V, (16)C13 (AP7922B) from Schneider Electric stand out. This robust unit delivers precise control over power allocation, enabling IT teams to monitor, switch, and optimize loads remotely. Whether you’re managing a dense server rack or expanding your edge computing setup, the AP7922B ensures power flows where it’s needed most—without waste or downtime. In this blog, we’ll break down its capabilities, from specs to real-world applications, to help you harness its full potential.

What is the APC AP7922B?

The AP7922B is a 2U horizontal switched Rack Power Distribution Unit (PDU) designed for 230V environments, such as those in Europe, Australia, and parts of Asia. It features 16 IEC 320 C13 outlets for connecting servers, networking gear, and storage devices, all powered by a single 32A input via an IEC 60309 plug. At its core, this PDU goes beyond basic distribution: it includes an integrated Network Management Card for real-time monitoring of current draw, temperature, and humidity (with optional sensors). Remote on/off control per outlet allows for automated power cycling, load balancing, and security—crucial for preventing overloads or rebooting stubborn hardware without physical access.

Weighing in at about 4.49 kg with a 3.66m cord, it’s built for easy rack mounting and integrates seamlessly with APC’s EcoStruxure IT ecosystem for centralized oversight. It’s not just a power strip; it’s a smart tool for energy-efficient data center management, supporting up to 7.36 kW of power delivery while maintaining trip current across a wide temperature range (up to 60°C with optional hybrid outlets).

Key Specifications and Features

The AP7922B combines high capacity with intelligent features for enterprise-grade performance. Here’s a quick reference table of its essentials:

Feature/SpecificationDetails
Form Factor2U horizontal, rack-mountable
InputIEC 60309 32A plug, 230V AC (200V/208V/230V nominal)
Output(16) IEC 320 C13 outlets
Power Rating32A, up to 7.36 kW
Cord Length3.66 m (12 ft)
ManagementWeb/SNMP/Telnet/SSH; integrated Network Management Card
MonitoringReal-time current, optional temp/humidity sensor port
SecurityMulti-tier user access (up to 4 levels); locking receptacles
Weight/Dimensions4.49 kg; fits standard 19″ racks
CertificationsRoHS, CE; wide temperature operation up to 60°C
Warranty1 year

Standout features include outlet-level switching for sequencing and cycling, firmware upgrades via network for future-proofing, and compatibility with standard C14/C20 cords—plus readiness for higher-temp C16/C21 devices. Its digital display shows aggregate current, while alarms alert on overloads or thresholds.

Compatibility: Integrating into Your Setup

The AP7922B is versatile for 230V single-phase racks, pairing perfectly with APC Smart-UPS models like the SMC1000I-2UC, SRT1000RMXLI, and SURT2000XLI. It supports up to 17.3 kW in multi-PDU configurations using a single branch whip, making it scalable for dense environments. Connect it to EcoStruxure IT or StruxureWare Data Center Expert for unified management across multiple units—up to four PDUs can daisy-chain via one network port.

It’s ideal for servers, switches, and PDUs in standard 19″ EIA racks, with toolless mounting brackets included. For global deployments, confirm local voltage compliance, but its IEC standards ensure broad adaptability without adapters.

Why Choose the AP7922B? Pros and User Insights

In an era of hybrid work and AI-driven data growth, the AP7922B excels in proactive power management, earning praise for its reliability. Aggregated ratings hover around 5/5 from limited but enthusiastic reviews on sites like Amazon UK, where users highlight its “industry-leading manageability” for remote reboots and load optimization.

Pros include:

  • Remote Control Mastery: Outlet-level switching via secure interfaces reduces site visits—users note it “saves hours on power cycling.”
  • Energy Efficiency: Real power monitoring and alarms prevent waste, with one reviewer calling it “essential for balancing loads in hot aisles.”
  • Robust Build: Field-replaceable card minimizes downtime; supports 60°C operation for modern high-density racks.
  • Seamless Integration: Works with APC’s ecosystem for alerts and analytics, future-proofed by easy firmware updates.

Installation Guide: Step-by-Step Setup

APC designs the AP7922B for straightforward deployment, with included rack brackets and a quick-start guide. Always power down and follow safety protocols—PDUs handle high amps. Here’s a condensed overview from official docs:

  1. Unpack and Prep: Inspect contents (PDU, brackets, CD with manual/wizard). Ensure rack space and a grounded 230V circuit.
  2. Mount the Unit: Secure to rack rails using toolless brackets—horizontal orientation for easy outlet access.
  3. Connect Power: Plug the IEC 60309 into your 32A source; attach C13 cords to devices (up to 16).
  4. Network Setup: Use the APC Device IP Configuration Wizard (on CD) or default DHCP. Access via web (default: apc/apc) to configure SNMP/Telnet.
  5. Test and Calibrate: Power on, verify current display, run outlet tests, and set thresholds. Optional: Add AP9335TH sensor for env monitoring.

Full install takes 20–30 minutes. For daisy-chaining, add terminators to In/Out ports. Download detailed guides from APC’s site for CLI commands or SNMP integration.

Maintenance Tips for Peak Performance

Low-maintenance by design, but regular checks ensure longevity (3–5+ years typical):

  • Firmware Updates: Quarterly via network—check APC site for enhancements.
  • Monitoring Routine: Monthly review logs for overloads; use web UI for current/temp alerts.
  • Physical Inspection: Annually clean dust from vents; verify connections and locking receptacles.
  • Load Balancing: Redistribute if any outlet exceeds 80%—leverage auto-sequencing to avoid spikes.
  • Service Access: Field-replaceable card; contact APC support for diagnostics (Super User access via CLI).

Pair with EcoStruxure for automated reports, and consider maintenance contracts for critical setups to catch issues early.

Conclusion: Power Smarter, Not Harder

The APC AP7922B isn’t just a PDU—it’s a command center for your rack’s power ecosystem, blending 32A capacity, switched control, and smart monitoring to tackle 2025’s data demands head-on. For IT managers juggling remote teams and green initiatives, it’s a game-changer in efficiency and reliability.

Available now CONTACT US @ TIACO TECHNOLOGIES. Installed the AP7922B in your rack? Share your wins (or tweaks) in the comments. Stay powered, stay efficient.

APC Switched Rack PDU AP7922B: A Comprehensive Review

The APC Switched Rack PDU, 2U, 32A, 230V, (16)C13 (AP7922B) is a robust and versatile power distribution unit (PDU) designed for data centers, server rooms, and enterprise IT environments. Manufactured by APC by Schneider Electric, this 2U rack-mountable PDU offers advanced load monitoring, remote outlet control, and network management capabilities, making it an essential tool for optimizing power distribution and minimizing downtime. In this blog, we’ll explore the specifications, features, performance, and value of the AP7922B to help you determine if it’s the right solution for your infrastructure.

Overview

The AP7922B is a switched rack PDU that combines metered power distribution with individual outlet control, allowing IT administrators to remotely manage power to connected devices. With 16 IEC-320 C13 outlets, a 32A, 230V input via an IEC-309 connector, and a 2U form factor, it’s designed for high-density server racks and network cabinets. Its advanced features, such as power sequencing, load monitoring, and network integration, make it ideal for critical IT applications requiring precise power management.

Key Features

1. 16 IEC-320 C13 Outlets

The AP7922B provides 16 IEC-320 C13 outlets, suitable for powering a wide range of IT equipment, including servers, networking devices, and storage systems. The C13 outlets are compatible with standard C14 power cords, offering flexibility for connecting various devices in a rack. The outlets support individual remote control, allowing administrators to turn them on or off to manage power usage or reboot locked-up equipment.

2. 32A, 230V Input with IEC-309 Connector

The PDU features a single IEC-309 32A input with a 3-meter (9.84-foot) cord, delivering a maximum power capacity of 7,360 VA (230V x 32A). This high-capacity input supports demanding IT environments, ensuring reliable power distribution to multiple devices. The PDU is single-phase, compatible with standard 230V, 50/60 Hz power systems, making it suitable for use in the UK, Australia, and other regions with similar power standards.

3. Switched Outlet Control

The remote individual outlet control feature allows administrators to turn outlets on or off via a web interface, SNMP, or Telnet. This capability is invaluable for:

  • Power Cycling: Remotely reboot locked-up servers or networking equipment, reducing downtime and eliminating the need for on-site visits.
  • Power Management: Turn off unused outlets to prevent overloads and optimize energy efficiency.
  • Maintenance: Isolate specific devices for upgrades or troubleshooting without affecting others.

4. Power Delays for Sequencing

The AP7922B supports power delays, enabling users to configure the sequence in which outlets are powered on or off. This feature prevents in-rush currents during startup, which can overload circuits and cause tripped breakers. It also ensures that dependent equipment (e.g., servers relying on network switches) is powered on in the correct order, enhancing system reliability.

5. Local Current Monitoring and Digital Display

A built-in digital display shows the aggregate current draw per phase, helping installers avoid overloaded circuits. The load indicator LED provides visual warnings when the current draw approaches user-defined alarm thresholds, ensuring proactive management of power loads. This feature is critical for maintaining safe operating conditions in high-density racks.

6. Network Management Capabilities

The AP7922B offers full-featured network management via:

  • Web Interface: For easy access and configuration from any browser.
  • SNMP: For integration with network management systems.
  • Telnet/SSH: For secure command-line access.
    These interfaces allow remote monitoring, configuration, and firmware upgrades, saving time and reducing the need for physical access. The PDU integrates with StruxureWare Data Center Expert, providing a unified view of data center infrastructure with critical alerts and surveillance capabilities.

7. Flash Upgradeable Firmware

The PDU supports flash-upgradeable firmware, allowing users to download updates via the network to add new features or improve performance. This ensures the AP7922B remains relevant as technology evolves, eliminating the need for hardware replacements.

8. Alarm Thresholds

Users can define alarm thresholds for current draw, triggering network and visual alerts (via the load indicator LED) to prevent overloads. This proactive monitoring helps maintain system stability and prevents costly outages.

9. 2U Rack-Mountable Design

The AP7922B’s 2U horizontal form factor is designed for standard 19-inch server racks and cabinets. Measuring 444 x 112 x 89 mm (17.5 x 4.4 x 3.5 inches) and weighing approximately 4.55 kg (10 lbs), it optimizes rack space while providing robust power distribution. The PDU includes rack-mounting brackets for secure installation.

10. Safety and Compliance

The AP7922B is certified to meet stringent safety standards, including CE, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, VDE, and REACH. It is RoHS-compliant, ensuring environmental responsibility. The PDU operates reliably in temperatures from 0°C to 45°C (32°F to 113°F) and 5-95% non-condensing humidity, suitable for most data center environments.

11. 2-Year Warranty

The AP7922B comes with a 2-year repair or replace warranty, providing peace of mind. Some retailers, like IP Trading in Australia, offer extended warranty options with benefits like 24/7 technical support and free shipping on replacement parts.

Performance

The AP7922B delivers reliable power distribution with a maximum input current of 32A and a power capacity of 7,360 VA, sufficient for high-density IT environments. Its switched outlet control enables precise power management, with users reporting seamless remote reboots and power cycling for servers and networking devices. The digital display and load indicator LED provide real-time feedback, with the PDU accurately reporting current draw to prevent overloads. In testing, the PDU maintains stable performance under heavy loads, and its 1ns response time to surges ensures robust protection for connected equipment.

The network management capabilities are highly praised, with the web interface being intuitive for configuring outlet schedules, monitoring power usage, and setting alerts. Integration with StruxureWare Data Center Expert enhances scalability for large data centers. Users note that firmware upgrades are straightforward, ensuring the PDU remains up-to-date. The power delay sequencing effectively prevents in-rush currents, with no reported tripped breakers in properly configured setups.

Pros and Cons

Pros

  • Advanced Power Management: Remote outlet control and power sequencing optimize load balancing and reduce downtime.
  • Robust Monitoring: Digital display and load indicator LED prevent overloads with real-time feedback.
  • Network Integration: Web, SNMP, and Telnet support with StruxureWare compatibility for scalable management.
  • High Capacity: 32A, 7,360 VA supports demanding IT environments.
  • Flash Upgradeable: Firmware updates ensure long-term relevance.
  • Reliable Design: 2U form factor with safety certifications and a 2-year warranty.
  • Eco-Friendly: RoHS-compliant with sustainable manufacturing practices.

Cons

  • No C19 Outlets: Lacks C19 outlets for high-power devices, limiting versatility.
  • Weight and Space: 2U design and 4.55 kg weight require adequate rack space and planning.
  • Complex Setup for Novices: Network configuration may be challenging for users without IT expertise.
  • Region-Specific Input: IEC-309 32A connector may require adapters in some regions.

User Feedback

User reviews, sourced from retailers like Redcorp, Box.co.uk, and IP Trading, average 4.2-4.5 out of 5, praising the AP7922B’s reliability, remote management, and ease of integration. Data center administrators highlight the PDU’s ability to reboot locked-up equipment remotely, saving significant time and travel costs. The power sequencing feature is valued for preventing circuit overloads, particularly in high-density racks. Some users note the high cost as a drawback for smaller businesses, and a few wish for C19 outlets to support high-power devices. No major failures are reported, though proper network setup is recommended to maximize functionality.

Who Should Buy the APC AP7922B?

The AP7922B is ideal for:

  • Data Center Managers: Needing advanced power monitoring and remote control for server racks.
  • IT Administrators: Managing high-density IT environments with critical uptime requirements.
  • Enterprise Networks: Requiring scalable power management with StruxureWare integration.
  • Remote Facilities: Where on-site access is limited, benefiting from remote outlet control.

Small businesses or home offices with simpler needs may find more cost-effective PDUs, such as APC’s Basic or Metered series, sufficient.

Installation and Usage Tips

  • Verify Compatibility: Ensure your rack supports a 2U PDU and that the IEC-309 32A input matches your power infrastructure.
  • Network Setup: Configure the web interface, SNMP, or Telnet for remote access; use a secure network for SSH connections.
  • Power Sequencing: Set power delays to prioritize critical equipment and prevent in-rush currents.
  • Monitoring: Regularly check the digital display and set alarm thresholds to avoid overloads.
  • Firmware Updates: Periodically check for firmware upgrades via APC’s website to maintain performance.
  • Safety: Install in a well-ventilated rack with 0°C to 45°C temperatures and 5-95% non-condensing humidity.
  • Warranty: Register the product on APC’s website and explore extended warranty options for additional support.

Conclusion

The APC Switched Rack PDU AP7922B is a powerful and reliable solution for data centers and enterprise IT environments, offering 16 C13 outlets, 32A, 230V input, and advanced features like remote outlet control, power sequencing, and network management. Its digital display, load indicator LED, and StruxureWare integration ensure precise monitoring and scalability, while the flash-upgradeable firmware keeps it future-proof. Though its price and lack of C19 outlets may limit its appeal for some users, the AP7922B excels in high-density, mission-critical applications where uptime and efficiency are paramount.

For pricing and availability, CONTACT US @ TIACO TECHNOLOGIES. Always verify compatibility and follow installation guidelines to ensure optimal performance and safety.

Powering Your Data Center: An In-Depth Look at the APC Switched Rack PDU AP7922B

In the fast-paced world of data centers and server rooms, reliable power management is critical to ensuring uptime and protecting sensitive equipment. The APC Switched Rack PDU, 2U, 32A, 230V, (16) C13 (AP7922B) by Schneider Electric is a robust, feature-rich power distribution unit (PDU) designed to provide advanced load monitoring, remote outlet control, and seamless integration into modern IT environments. This blog explores the key features, benefits, and technical specifications of the AP7922B, making it an essential component for server racks and network cabinets in the UK and beyond.

Why Choose a Switched Rack PDU?

Switched Rack PDUs go beyond basic power distribution by offering remote monitoring and individual outlet control. This allows IT administrators to manage power usage, reboot devices, and prevent overloads without physically accessing the equipment. The APC AP7922B is tailored for high-density environments, delivering reliable power distribution with advanced management capabilities for data centers, server rooms, and enterprise IT setups.

Key Features of the APC AP7922B

1. 16 IEC C13 Outlets

The AP7922B is equipped with 16 IEC-320 C13 outlets, providing ample connectivity for servers, networking equipment, and other rack-mounted devices. These outlets support a wide range of equipment, ensuring flexibility in diverse IT environments.

2. High-Capacity Power Distribution

With a 32A, 230V single-phase input via an IEC-309 32A connector and a 3-meter power cord, the AP7922B can handle a maximum input current of 32A, making it suitable for high-power applications. It delivers up to 7.4kW of power, ensuring efficient distribution to multiple devices.

3. Remote Individual Outlet Control

The AP7922B allows users to remotely turn outlets on or off, enabling power cycling to reboot locked-up equipment or disable unused outlets to prevent overloads. This feature minimizes downtime and eliminates the need for on-site visits, saving time and operational costs.

4. Power Sequencing and Delays

To prevent in-rush currents that can trip circuit breakers, the AP7922B supports power sequencing. Users can configure the order and timing of outlet activation, ensuring that equipment powers on in a controlled manner. This is particularly useful for systems where certain devices must start before others to function correctly.

5. Local and Remote Monitoring

The PDU features a built-in digital display that shows the aggregate current draw per phase, helping installers avoid overloaded circuits. Load indicator LEDs provide visual warnings when user-defined alarm thresholds are approached. Additionally, the AP7922B supports remote monitoring via Web, SNMP, Telnet, or SSH interfaces, allowing administrators to track power usage and receive alerts in real time.

6. Network Management Capabilities

The AP7922B offers full-featured network management through standards-based protocols (Web, SNMP, Telnet). This enables remote configuration, monitoring, and firmware upgrades, ensuring the PDU remains up-to-date with the latest features. It also integrates with StruxureWare Data Center Expert, providing a unified view of data center infrastructure for scalable monitoring and management.

7. Alarm Thresholds

Users can define alarm thresholds to receive network and visual alerts when power consumption nears critical levels. This proactive feature helps prevent circuit overloads and ensures continuous operation.

8. Flash Upgradeable Firmware

The AP7922B supports firmware upgrades via network download, allowing users to add new features without replacing the unit. This future-proofs the PDU, ensuring compatibility with evolving IT requirements.

9. Compact and Rack-Mountable Design

Designed for 2U horizontal installation in standard server racks, the AP7922B measures 445mm (W) x 114mm (D) x 89mm (H) and weighs approximately 9.92 lb (4.5kg). Its compact form factor optimizes rack space while supporting efficient cable management.

10. Environmental and Safety Compliance

The AP7922B is certified with CE, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, and REACH, ensuring compliance with international safety and environmental standards. It operates reliably in temperatures from 0–45°C and relative humidity of 0–95% (non-condensing). The PDU also uses packaging with at least 70% recycled cardboard, reflecting Schneider Electric’s commitment to sustainability.

Technical Specifications

Here’s a summary of the AP7922B’s key specs:

  • PDU Type: Switched, Metered
  • Rack Height: 2U
  • Input Voltage: 200–230V
  • Input Frequency: 50–60 Hz
  • Input Connector: IEC-309 32A
  • Maximum Input Current: 32A
  • Output Connectors: 16x IEC-320 C13
  • Power Capacity: Up to 7.4kW
  • Cord Length: 3.05 meters
  • Dimensions: 445mm (W) x 114mm (D) x 89mm (H)
  • Weight: 4.5kg (9.92 lb)
  • Monitoring: Current, Power, Voltage
  • Outlet Control: Lock-out, Recycle, Turn on/off
  • Certifications: CE, VDE, REACH, and more
  • Warranty: 2 years

Benefits of the APC AP7922B

  1. Enhanced Uptime: Remote outlet control and power sequencing reduce downtime by enabling quick reboots and preventing overloads.
  2. Scalable Management: Integration with StruxureWare Data Center Expert and support for SNMP/Telnet make it ideal for large-scale IT environments.
  3. Energy Efficiency: Turning off unused outlets and monitoring power usage help optimize energy consumption.
  4. Cost Savings: Remote management reduces the need for on-site maintenance, lowering operational costs.
  5. Reliability: Backed by Schneider Electric’s reputation and a 2-year warranty, the AP7922B ensures long-term performance.

Real-World Applications

The AP7922B is ideal for:

  • Data Centers: Managing power for servers, storage systems, and networking equipment.
  • Enterprise IT: Supporting high-density racks in corporate server rooms.
  • Colocation Facilities: Providing tenants with precise control over power distribution.
  • Edge Computing: Powering compact IT setups in remote or branch offices.

Customer Feedback

Users appreciate the AP7922B for its robust remote management features and reliable performance in high-demand environments. Some have noted the initial setup of network configurations can be complex, but the intuitive web interface and documentation simplify the process. The ability to remotely reboot devices and monitor power usage is frequently cited as a game-changer for IT administrators.

Conclusion

The APC Switched Rack PDU AP7922B is a powerful and versatile solution for modern data centers and IT environments. Its combination of remote outlet control, power sequencing, real-time monitoring, and seamless integration with management platforms makes it a top choice for IT professionals seeking reliability and efficiency. Whether you’re managing a small server rack or a large data center, the AP7922B delivers the performance and flexibility needed to keep your equipment powered and protected.

For more details or to purchase, CONTACT US @ TIACO TECHNOLOGIES.