A Comprehensive Look at the APC Switched Rack PDU AP7922B

In the high-stakes world of IT infrastructure, where servers hum 24/7 and downtime can cost thousands per minute, power management isn’t just a nice-to-have—it’s mission-critical. Enter the APC Switched Rack PDU AP7922B, a 2U powerhouse designed to deliver precise control over power distribution in your rack environment. Tailored for 230V setups with a robust 32A capacity, this unit features 16 C13 outlets and advanced switching capabilities, making it ideal for data centers, server rooms, or enterprise edge computing. As part of APC’s (Schneider Electric) renowned NetShelter lineup, the AP7922B combines reliability with smart monitoring to keep your operations running smoothly. Let’s break down what makes this PDU a game-changer.

Key Features That Drive Efficiency

The AP7922B stands out for its blend of rugged hardware and intelligent software, empowering IT admins with tools to optimize power usage and prevent issues before they escalate. Here’s a spotlight on its standout capabilities:

  • Outlet-Level Switching: Remotely turn individual outlets on or off via Ethernet—perfect for rebooting stubborn servers without physical access or sequencing power-ups to avoid inrush currents.
  • Real-Time Power Monitoring: Track current, voltage, and power draw at the outlet level, with user-defined alarms for thresholds like overloads or underutilization.
  • Power Sequencing: Automatically stagger outlet activation to protect equipment from damaging surges during startup, a boon for dense rack configurations.
  • Temperature/Humidity Sensor Port: Connect APC’s environmental sensors for holistic monitoring, helping maintain optimal conditions in your enclosure.
  • Locking IEC Receptacles: Secure C13 outlets prevent accidental unplugging, ensuring uptime in vibration-prone environments.
  • Compact 2U Design: Fits seamlessly into standard 19-inch racks, with a 10-foot cord for flexible installation and horizontal/vertical mounting options.

These features adhere to industry standards, including UL and IEC certifications, ensuring compatibility and safety in global deployments.

Technical Specifications at a Glance

For those diving deeper, the AP7922B’s specs reflect APC’s engineering prowess. We’ve compiled them into this easy-reference table:

SpecificationDetails
ModelAPC AP7922B (AP8000 Series)
Form Factor2U Rack-Mountable
Input Voltage200V / 208V / 230V AC
Input Current32A
Input ConnectorIEC 309 32A (2P+E)
Output Voltage230V AC
Output Outlets16 x IEC C13
Cord Length10 feet (3m)
Dimensions (H x W x D)89 mm x 445 mm x 114 mm
Weight4.5 kg
Management InterfaceEthernet 10/100BaseT
Operating TemperatureUp to 60°C at full load (hybrid outlets)
CertificationsUL, IEC, RoHS

This setup supports a maximum load of around 7.36 kW, making it suitable for mid-sized racks without overwhelming your circuit.

The Real-World Benefits: Control, Uptime, and Savings

Imagine a midnight alert: a server in your remote colo facility is unresponsive. With the AP7922B, you log into its web interface from your phone, cycle the outlet, and it’s back online—no frantic calls to on-site techs. This remote control slashes mean time to repair (MTTR) and reduces travel costs, especially in distributed setups.

For energy-conscious ops, the monitoring tools help identify power hogs, enabling load balancing that can cut electricity bills by 10-20% in optimized environments. The fail-safe design, including overload protection and auto-disconnect, guards against costly hardware failures. Plus, its eco-friendly build (RoHS compliant) aligns with green IT goals, minimizing e-waste.

In high-density scenarios, like edge computing or virtualization farms, the sequencing prevents the “big bang” overload from simultaneous boots, extending equipment life. Overall, it’s a scalable solution that grows with your infrastructure.

What Users Are Saying

Feedback on the AP7922B highlights its reliability in demanding setups. On Amazon, it holds strong ratings for build quality and ease of integration, with users noting the “intuitive web UI for quick reboots.” Data center pros praise the remote management, calling it “a lifesaver for high-demand environments” where downtime is non-negotiable. One reviewer appreciated the locking outlets: “No more loose plugs in our vibrating racks—solid uptime boost.” Common pros include robust monitoring and sequencing; a minor con is the lack of built-in Wi-Fi (Ethernet only). With an average of 4.5+ stars across sites, it’s a trusted pick for pros.

Final Thoughts: Secure Your Power, Secure Your Future

The APC AP7922B isn’t just a PDU—it’s a smart guardian for your rack’s power ecosystem, blending switched control with precise monitoring to deliver unmatched efficiency and peace of mind. It’s an investment that pays off in reduced downtime and smarter resource use, especially for 230V international deployments.

Whether you’re outfitting a new data center or upgrading legacy gear, this 2U switched unit from APC’s AP8000 series is worth the rack space. CONTACT US @ TIACO TECHNOLOGIES – your servers will run cooler and longer.

The APC Switched Rack PDU AP7922B

In the high-stakes world of data centers and server rooms, precise power distribution and remote management are key to maintaining uptime and efficiency. The APC Switched Rack PDU AP7922B, a 2U horizontal unit from Schneider Electric, delivers exactly that—offering 32A at 230V with 16 IEC C13 outlets for seamless power delivery to rack-mounted equipment. Designed for single-phase setups, this metered and switched PDU enables IT admins to monitor loads in real-time, cycle power remotely, and prevent overloads, all while integrating effortlessly into existing networks. Whether you’re optimizing a colocation facility or fortifying an enterprise server rack, the AP7922B combines robust performance with user-friendly controls to future-proof your power strategy.

Key Features That Drive Efficiency

The AP7922B stands out with its blend of hardware reliability and software intelligence, making power management intuitive and proactive. Standout elements include:

  • Outlet-Level Switching: Remotely turn outlets on/off individually to reboot devices, restrict access, or sequence power-up for safe startups—ideal for troubleshooting without on-site visits.
  • Real-Time Monitoring: Tracks current, voltage, and power metrics per outlet and overall, with customizable thresholds for alerts on potential issues.
  • Secure Network Interfaces: Supports Web, SNMP, Telnet, and CLI for configuration, plus integration with APC’s StruxureWare platforms like Data Center Expert for centralized oversight.
  • Wide Input/Output Flexibility: Handles 220-240V inputs and outputs 230V AC, with a 3.05m cable and IEC 60309 input plug for easy installation in global setups.
  • Durable Rack Design: 2U form factor with front-to-rear airflow compatibility, ensuring it fits standard 19-inch racks without compromising cooling.
  • Advanced Protocols and Security: Features user authentication, event logging, and firmware upgradability to keep your infrastructure secure and current.

These capabilities transform the AP7922B from a simple power strip into a smart tool for dynamic IT environments.

Technical Specifications at a Glance

Here’s a compiled overview of the AP7922B’s core specifications, based on official product data:

CategoryDetails
Power Rating32A, 7360 VA (single-phase)
Input Voltage200V / 208V / 230V (220-240V adjustable)
Output Voltage230V AC
Frequency50/60 Hz
Outlets16 x IEC 320 C13
Input ConnectionIEC 60309 309 plug
Cable Length3.05 m
Dimensions (H x W x D)89 mm x 445 mm x 114 mm (3.5″ x 17.5″ x 4.5″)
Weight4.5 kg (net)
Rack Units2U horizontal
Operating Temperature0–45°C; Humidity: 0–95% non-condensing
CertificationsCE, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, REACH
Management ProtocolsHTTP/HTTPS, SNMP v1/v3, Telnet, SSH, CLI
Warranty1 year (repair or replace)

This PDU supports up to 14.4kW in similar APC families, but the AP7922B’s 7.36kVA rating suits mid-sized racks perfectly.

Benefits and Ideal Use Cases

The AP7922B shines by reducing operational overhead—remote controls cut travel time for reboots, while metering helps optimize energy use and avoid spikes that could trip breakers. Its switched functionality supports power-on sequencing to protect hardware during startups, and integration with EcoStruxure IT enables predictive maintenance. As a RoHS-compliant unit, it aligns with green initiatives, it delivers strong ROI through minimized downtime.

It’s tailored for:

  • Data Centers: Monitors and manages dense server clusters with per-outlet granularity.
  • Enterprise IT Rooms: Enables remote power cycling for distributed teams handling edge computing.
  • Colocation Facilities: Provides secure, auditable access controls for multi-tenant environments.
  • Network Cabinets: Distributes power to switches and storage in telecom or financial setups.

IT pros value its intuitive web interface for quick setups and reliable performance under load.

Wrapping Up: Precision Power for Demanding Racks

The APC Switched Rack PDU AP7922B is a powerhouse of control and insight, empowering IT teams to handle power like never before. With its 2U efficiency, 16 switched outlets, and robust monitoring, it’s a must-have for any rack demanding reliability and remote smarts. Elevate your infrastructure today—CONTACT US @ TIACO TECHNOLOGIES for availability and accessories.

APC Switched Rack PDU AP7922B

In the dense, high-stakes world of data centers and server rooms, where every watt counts and downtime is measured in dollars, intelligent power distribution is the unsung hero of efficiency. The APC Switched Rack PDU AP7922B—a 2U, 32A, 230V unit with 16 C13 outlets—delivers precisely that: switched, metered control over power delivery to your rack-mounted gear. From Schneider Electric’s robust APC NetShelter lineup, this PDU empowers IT admins to remotely cycle outlets, monitor loads in real-time, and sequence power-ups to prevent inrush overloads. As we roll through September 2025 with escalating demands on edge computing and AI workloads, the AP7922B remains a cornerstone for scalable, secure power management. In this blog, we’ll unpack its specs, standout features, deployment tips, and why it’s a favorite among data center pros.

What Is the APC AP7922B Switched Rack PDU?

The AP7922B is a horizontal, rack-mountable Switched Rack PDU designed for single-phase 230V environments, distributing up to 7360VA of power across 16 IEC C13 outlets. It features an integrated current sensor for per-phase metering and individual outlet switching, allowing granular control over connected devices like servers, switches, and storage arrays. Input comes via a durable IEC 60309 32A plug on a 3.05m cord, making it plug-and-play for standard European racks.

It includes mounting hardware, a network cable, and access to APC’s EcoStruxure IT for centralized oversight. With a 1-year warranty and flash-upgradeable firmware, it’s built for longevity in 19-inch racks, occupying just 2U of vertical space. This PDU shines in mid-sized setups, bridging basic PDUs and full enterprise metered units.

Key Features and Specifications

The AP7922B combines robust hardware with smart networking for proactive power governance. Here’s a snapshot of its core specs:

FeatureDescriptionBenefit
Capacity & Input7360VA max; 32A single-phase; IEC 60309 32A input plug; 3.05m cordHandles high-density loads up to 230V without derating; Flexible for global 200-230V grids.
Output16x IEC C13 outlets; 230V ACPowers standard IT equipment; Switched control per outlet for targeted on/off.
Metering & SwitchingPer-phase current monitoring; Outlet-level switchingReal-time load tracking via web/SNMP; Remote rebooting without physical access.
Management InterfacesEthernet 10/100; Web, SNMP, Telnet, SSH; StruxureWare integrationSecure remote config; Firmware upgrades over network for future-proofing.
Physical Specs2U horizontal; 444 x 114 x 203 mm (W x H x D); ~8kg; Black metal housingFits standard 19″ racks; Compact for dense deployments with passive cooling.
Safety & AlarmsOverload thresholds; Network/visual alerts; Power delays/sequencingPrevents circuit trips; Email/SNMP notifications for proactive issue resolution.
CertificationsIEC 62040-2; CE; RoHSGlobal compliance for safe, eco-friendly operation in regulated environments.

These elements make it a versatile choice, with up to 98% efficiency in bypass modes and support for up to four PDUs on a single network drop via port sharing.

Why Choose the AP7922B? Benefits for Your Data Center

In 2025’s power-constrained landscapes, the AP7922B elevates rack management from reactive to strategic:

  • Granular Remote Control: Switch individual outlets via web or CLI to reboot hung servers or schedule maintenance, slashing MTTR in distributed teams.
  • Load Optimization: Real-time metering and alarm thresholds spot imbalances early, avoiding overloads and enabling capacity planning for growing AI/ML clusters.
  • Sequenced Power Management: Programmable delays prevent startup surges, protecting circuits and extending hardware life—ideal for hot-swappable environments.
  • Seamless Integration: Ties into EcoStruxure for holistic DCIM, supporting SNMPv3 for secure, standards-based oversight without added costs.

Admins report up to 30% better utilization in racks, turning power from a bottleneck into a boon for efficiency and sustainability.

Installation: A Streamlined Guide

The AP7922B’s rack-ready design simplifies deployment, often in under 30 minutes. Always follow APC’s manual, but here’s the essentials (engage a qualified electrician for hardwiring if needed):

  1. Rack Prep: Secure 2U space in a 19″ enclosure with adequate airflow. Verify 230V/32A feed availability.
  2. Mount the PDU: Use included rails or brackets to install horizontally. Connect the IEC 60309 plug to your upstream source (e.g., UPS or panel).
  3. Cable Up: Plug devices into C13 outlets, grouping critical loads. Attach Ethernet for management—default IP via DHCP.
  4. Configure Access: Log in via web (user: apc, pass: apc), set thresholds, and enable SNMP. Test switching and metering with a load simulator.
  5. Integrate & Test: Link to StruxureWare if using; Run a full self-test for alarms. Pro tip: Sequence outlets for boot order to mimic production.

APC’s online guides and videos cover edge cases like firmware flashes.

Real-User Insights: What Data Center Pros Are Saying

The AP7922B scores high for reliability, with eBay and reseller averages around 4.5/5 from enterprise buyers. One FaithJCom reviewer gave it 5/5: “With industry-leading reliability… advanced load management plus on/off outlet level power cycling,” praising its role in secure remote ops. On Comms Express, users highlight integration: “Full-featured network management… save valuable time,” noting seamless StruxureWare ties.

Is the AP7922B Right for You? Final Thoughts

For IT teams managing 5-20kW racks in 230V setups, the APC Switched Rack PDU AP7922B is a powerhouse of control and insight—delivering switched precision without the complexity of higher-end models. Its metering smarts, remote accessibility, and APC ecosystem make it indispensable for efficient, resilient infrastructure amid rising power demands.

CONTACT US @ TIACO TECHNOLOGIES for bundles with sensors. Powered your rack with one? Share your load stories in the comments!

APC Switched Rack PDU AP7922B

In the high-stakes world of data centers and server rooms, reliable power distribution is the backbone of uninterrupted operations. As demands for efficiency, remote management, and scalability grow in 2025, switched PDUs like the APC Rack PDU, Switched, 2U, 32A, 230V, (16)C13 (AP7922B) from Schneider Electric stand out. This robust unit delivers precise control over power allocation, enabling IT teams to monitor, switch, and optimize loads remotely. Whether you’re managing a dense server rack or expanding your edge computing setup, the AP7922B ensures power flows where it’s needed most—without waste or downtime. In this blog, we’ll break down its capabilities, from specs to real-world applications, to help you harness its full potential.

What is the APC AP7922B?

The AP7922B is a 2U horizontal switched Rack Power Distribution Unit (PDU) designed for 230V environments, such as those in Europe, Australia, and parts of Asia. It features 16 IEC 320 C13 outlets for connecting servers, networking gear, and storage devices, all powered by a single 32A input via an IEC 60309 plug. At its core, this PDU goes beyond basic distribution: it includes an integrated Network Management Card for real-time monitoring of current draw, temperature, and humidity (with optional sensors). Remote on/off control per outlet allows for automated power cycling, load balancing, and security—crucial for preventing overloads or rebooting stubborn hardware without physical access.

Weighing in at about 4.49 kg with a 3.66m cord, it’s built for easy rack mounting and integrates seamlessly with APC’s EcoStruxure IT ecosystem for centralized oversight. It’s not just a power strip; it’s a smart tool for energy-efficient data center management, supporting up to 7.36 kW of power delivery while maintaining trip current across a wide temperature range (up to 60°C with optional hybrid outlets).

Key Specifications and Features

The AP7922B combines high capacity with intelligent features for enterprise-grade performance. Here’s a quick reference table of its essentials:

Feature/SpecificationDetails
Form Factor2U horizontal, rack-mountable
InputIEC 60309 32A plug, 230V AC (200V/208V/230V nominal)
Output(16) IEC 320 C13 outlets
Power Rating32A, up to 7.36 kW
Cord Length3.66 m (12 ft)
ManagementWeb/SNMP/Telnet/SSH; integrated Network Management Card
MonitoringReal-time current, optional temp/humidity sensor port
SecurityMulti-tier user access (up to 4 levels); locking receptacles
Weight/Dimensions4.49 kg; fits standard 19″ racks
CertificationsRoHS, CE; wide temperature operation up to 60°C
Warranty1 year

Standout features include outlet-level switching for sequencing and cycling, firmware upgrades via network for future-proofing, and compatibility with standard C14/C20 cords—plus readiness for higher-temp C16/C21 devices. Its digital display shows aggregate current, while alarms alert on overloads or thresholds.

Compatibility: Integrating into Your Setup

The AP7922B is versatile for 230V single-phase racks, pairing perfectly with APC Smart-UPS models like the SMC1000I-2UC, SRT1000RMXLI, and SURT2000XLI. It supports up to 17.3 kW in multi-PDU configurations using a single branch whip, making it scalable for dense environments. Connect it to EcoStruxure IT or StruxureWare Data Center Expert for unified management across multiple units—up to four PDUs can daisy-chain via one network port.

It’s ideal for servers, switches, and PDUs in standard 19″ EIA racks, with toolless mounting brackets included. For global deployments, confirm local voltage compliance, but its IEC standards ensure broad adaptability without adapters.

Why Choose the AP7922B? Pros and User Insights

In an era of hybrid work and AI-driven data growth, the AP7922B excels in proactive power management, earning praise for its reliability. Aggregated ratings hover around 5/5 from limited but enthusiastic reviews on sites like Amazon UK, where users highlight its “industry-leading manageability” for remote reboots and load optimization.

Pros include:

  • Remote Control Mastery: Outlet-level switching via secure interfaces reduces site visits—users note it “saves hours on power cycling.”
  • Energy Efficiency: Real power monitoring and alarms prevent waste, with one reviewer calling it “essential for balancing loads in hot aisles.”
  • Robust Build: Field-replaceable card minimizes downtime; supports 60°C operation for modern high-density racks.
  • Seamless Integration: Works with APC’s ecosystem for alerts and analytics, future-proofed by easy firmware updates.

Installation Guide: Step-by-Step Setup

APC designs the AP7922B for straightforward deployment, with included rack brackets and a quick-start guide. Always power down and follow safety protocols—PDUs handle high amps. Here’s a condensed overview from official docs:

  1. Unpack and Prep: Inspect contents (PDU, brackets, CD with manual/wizard). Ensure rack space and a grounded 230V circuit.
  2. Mount the Unit: Secure to rack rails using toolless brackets—horizontal orientation for easy outlet access.
  3. Connect Power: Plug the IEC 60309 into your 32A source; attach C13 cords to devices (up to 16).
  4. Network Setup: Use the APC Device IP Configuration Wizard (on CD) or default DHCP. Access via web (default: apc/apc) to configure SNMP/Telnet.
  5. Test and Calibrate: Power on, verify current display, run outlet tests, and set thresholds. Optional: Add AP9335TH sensor for env monitoring.

Full install takes 20–30 minutes. For daisy-chaining, add terminators to In/Out ports. Download detailed guides from APC’s site for CLI commands or SNMP integration.

Maintenance Tips for Peak Performance

Low-maintenance by design, but regular checks ensure longevity (3–5+ years typical):

  • Firmware Updates: Quarterly via network—check APC site for enhancements.
  • Monitoring Routine: Monthly review logs for overloads; use web UI for current/temp alerts.
  • Physical Inspection: Annually clean dust from vents; verify connections and locking receptacles.
  • Load Balancing: Redistribute if any outlet exceeds 80%—leverage auto-sequencing to avoid spikes.
  • Service Access: Field-replaceable card; contact APC support for diagnostics (Super User access via CLI).

Pair with EcoStruxure for automated reports, and consider maintenance contracts for critical setups to catch issues early.

Conclusion: Power Smarter, Not Harder

The APC AP7922B isn’t just a PDU—it’s a command center for your rack’s power ecosystem, blending 32A capacity, switched control, and smart monitoring to tackle 2025’s data demands head-on. For IT managers juggling remote teams and green initiatives, it’s a game-changer in efficiency and reliability.

Available now CONTACT US @ TIACO TECHNOLOGIES. Installed the AP7922B in your rack? Share your wins (or tweaks) in the comments. Stay powered, stay efficient.

Powering Your Data Center: A Comprehensive Guide to the APC NetShelter Switched Rack PDU, 2U, 32A, 230V, (16)C13 (AP7922B)

In modern data centers and IT environments, reliable power distribution is critical to maintaining uptime and protecting sensitive equipment. The APC NetShelter Switched Rack PDU, 2U, 32A, 230V, (16)C13 (AP7922B), manufactured by APC by Schneider Electric, is a high-performance power distribution unit (PDU) designed to deliver robust power management for servers, networking gear, and other rack-mounted devices. With its switched outlets, remote monitoring capabilities, and compact 2U design, the AP7922B is a versatile solution for small to medium-sized data centers, enterprise IT setups, and colocation facilities. In this blog, we’ll explore the features, specifications, benefits, installation tips, and recent user feedback for the AP7922B to help you optimize your power infrastructure.

What is the APC NetShelter Switched Rack PDU AP7922B?

The APC AP7922B is a switched rack-mounted Power Distribution Unit (PDU) that provides advanced power control and monitoring for IT equipment. With a capacity of 32A at 230V, it features 16 IEC 60320 C13 outlets, enabling connectivity for a wide range of devices. The switched functionality allows individual outlet control, enabling remote power cycling to reboot equipment or restrict unauthorized use. Designed for 230V environments (common in Europe, Asia, and Australia), its 2U form factor and 10-foot cord make it ideal for rack installations. The AP7922B supports remote management via Web, SNMP, or Telnet interfaces, integrating seamlessly with APC’s centralized management platforms like EcoStruxure IT.

This PDU is perfect for environments requiring precise power control, such as data centers, server rooms, and network closets, ensuring both reliability and efficiency.

Key Features and Technical Specifications

The AP7922B is packed with features tailored for modern IT environments. Here’s a detailed look at its specifications:

  • Power Capacity: 7360 VA (32A at 230V)
  • Input Voltage: 200V, 208V, 230V (permissible range: 220–240V)
  • Input Connection: IEC 60309 32A 2P+E (10 ft / 3.05 m cord)
  • Output Connections: 16x IEC 60320 C13 outlets
  • PDU Type: Switched, allowing individual outlet on/off control
  • Form Factor: 2U rack-mounted, horizontal orientation
  • Physical Dimensions:
    • Height: 3.5 in (8.9 cm)
    • Width: 17.5 in (44.5 cm)
    • Depth: 4.5 in (11.4 cm)
    • Weight: 9.9 lbs (4.5 kg)
  • Mounting Options: Front or rear rack mounting with included brackets
  • Environmental Data:
    • Total lifecycle carbon footprint: 1814 kg CO2 equivalent
    • Packaged in recycled cardboard (minimum 70% recycled content)
    • Operating Temperature: 0–45°C
    • Operating Humidity: 0–95% (non-condensing)
    • Operating Altitude: 0–10,000 ft
  • Certifications: CE, GOST, IRAM, MIC, VDE
  • Standards Compliance: EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3
  • Management Features:
    • Remote monitoring and control via Web, SNMP, Command Line Interface, or Telnet
    • Integrates with StruxureWare Data Center Expert for centralized management
    • User-defined alarms for overload and environmental conditions
    • Load indicator LED for real-time monitoring
  • Provided Equipment: Documentation CD, installation guide, rack mounting brackets
  • Warranty: 1-year repair or replace warranty

Benefits of the APC NetShelter Switched Rack PDU AP7922B

The AP7922B offers numerous advantages for IT and facility managers:

  • Individual Outlet Control: Switched outlets allow remote power cycling, enabling quick reboots of hung devices or restricting access to specific outlets, reducing downtime.
  • High Power Capacity: Supports up to 7360 VA, ideal for power-hungry equipment like blade servers and networking gear.
  • Remote Monitoring and Management: Web, SNMP, and Telnet interfaces provide real-time load monitoring and alerts, integrating with platforms like EcoStruxure IT for streamlined operations.
  • Space-Efficient Design: The 2U form factor and 16 C13 outlets maximize rack space while supporting multiple devices.
  • Reliable Surge Protection: Built-in surge suppression and noise filtering protect equipment from power disturbances.
  • Eco-Conscious Features: Packaged in recycled materials and supports APC’s take-back program in select regions, aligning with sustainability goals.

How Does It Work?

The AP7922B distributes power from a single high-capacity input (32A, 230V) to 16 IEC C13 outlets, each of which can be individually controlled via a network interface. Its switched functionality allows users to turn outlets on or off remotely, sequence power delivery to prevent inrush currents, and monitor load levels in real time. The PDU uses a load indicator LED to warn of potential overloads and supports user-defined alarms for proactive management.

During operation, the unit filters out electrical noise and surges, ensuring clean power delivery to connected devices. The 10-foot IEC 60309 cord provides flexibility in rack placement, and the unit’s integration with management software like StruxureWare Data Center Expert enables centralized monitoring across multiple PDUs or sites. For example, during a server hang, an IT admin can remotely cycle power to a specific outlet, minimizing downtime without physical intervention.

Installation and Best Practices

Installing the AP7922B requires careful planning due to its high-power capacity and rack-mounted design:

  1. Site Preparation: Ensure the rack has sufficient space (2U) and access to a 230V, 32A circuit with an IEC 60309 outlet.
  2. Mounting: Secure the PDU to the rack using the included rack mounting brackets, either in the front or rear position, depending on cable management needs.
  3. Power Connection: Connect the IEC 60309 32A plug to a properly grounded outlet, ideally with a dedicated circuit.
  4. Device Connection: Plug critical equipment into the 16 IEC C13 outlets, prioritizing high-priority devices like servers and switches.
  5. Network Setup: Connect the PDU to the network via its Ethernet port and configure it using Web, SNMP, or Telnet interfaces. Integrate with StruxureWare or other management platforms for centralized control.
  6. Testing: Verify outlet functionality and test remote control features to ensure proper operation.

Tips:

  • Pair with an APC Ethernet surge protector (e.g., PNET1GB, as discussed in a previous blog) to protect data lines, complementing the PDU’s power protection.
  • Regularly monitor load levels via the management interface to avoid overloading (max 7360 VA).
  • Check APC’s website for firmware updates to enhance performance and compatibility.
  • Ensure proper grounding and circuit capacity to maximize safety and surge protection.

Conclusion

The APC NetShelter Switched Rack PDU, 2U, 32A, 230V, (16)C13 (AP7922B) is a powerful and versatile solution for data centers, server rooms, and IT environments requiring precise power control and monitoring. Its 7360 VA capacity, 16 switched C13 outlets, and advanced remote management capabilities make it ideal for managing high-density equipment. It’s a premium investment backed by a 1-year warranty and APC’s trusted reputation.

For the latest pricing and availability, CONTACT US @ TIACO TECHNOLOGIES. To complete your power protection strategy, consider pairing it with an APC Ethernet surge protector, as discussed in prior blogs. Keep your data center powered and protected with the AP7922B!

APC Rack PDU, Switched, 2U, 32A, 230V, (16)C13 (AP7922B): A Comprehensive Review

In modern data centers, server rooms, and IT environments, reliable power distribution is critical to maintaining uptime and protecting equipment. The APC Rack PDU, Switched, 2U, 32A, 230V, (16)C13 (AP7922B) by Schneider Electric is a high-performance power distribution unit (PDU) designed to deliver advanced power management, remote monitoring, and robust reliability. This blog post explores the specifications, features, performance, and value of the AP7922B, helping you decide if it’s the right solution for your power management needs.

Overview of the APC AP7922B Rack PDU

The AP7922B is part of APC’s Switched Rack PDU series, offering advanced power control and monitoring for IT equipment. With its 2U form factor, 16 IEC C13 outlets, and 32A capacity, this PDU is tailored for high-density server racks and network cabinets, providing individual outlet control, real-time monitoring, and seamless integration with data center management systems. Its robust design and network management capabilities make it a favorite among IT professionals and data center administrators.

Key Specifications

  • Input Voltage: 200V, 208V, 230V
  • Input Frequency: 50/60 Hz
  • Input Connection: IEC 60309 32A 2P+E (3-meter cord)
  • Maximum Input Current: 32A
  • Load Capacity: 7360 VA
  • Output Outlets: 16 IEC 60320 C13
  • Dimensions: 8.9 x 44.5 x 11.4 cm (3.5 x 17.5 x 4.5 inches)
  • Weight: 4.5 kg (9.92 lb)
  • Rack Height: 2U
  • Mounting: Horizontal, front or rear rack mounting
  • Certifications: CE, GOST, IRAM, MIC, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3
  • Operating Temperature: 0 to 45°C
  • Warranty: 2-year repair or replace warranty
  • Environmental Impact: 1814 kg CO2 equivalent (total lifecycle); packaging with minimum 70% recycled cardboard
  • Disposal: Included in Schneider Electric’s global take-back program (availability varies by country)

Key Features

1. Switched Outlet Control

The AP7922B features 16 individually controllable IEC C13 outlets, allowing users to remotely power on/off or reboot specific devices. This minimizes downtime by enabling remote power cycling of locked-up equipment and prevents unauthorized use of outlets, enhancing security and operational efficiency.

2. Power Sequencing Delays

To prevent circuit overloads during startup, the PDU supports configurable power sequencing delays. Users can define the order in which outlets are powered on or off, ensuring dependent equipment starts correctly and avoiding inrush current surges that could trip breakers.

3. Real-Time Current Monitoring

A built-in digital display provides real-time monitoring of the aggregate current draw per phase, helping installers avoid overloaded circuits. User-defined alarm thresholds trigger visual and network alerts when current draw approaches the maximum 32A limit, ensuring proactive management of power loads.

4. Network Management Capabilities

The AP7922B offers full-featured network management via Web, SNMP, Telnet, and SSH interfaces, allowing remote access, configuration, and monitoring. It integrates with APC’s StruxureWare Data Center Expert for centralized management, providing a unified view of power infrastructure. Firmware upgrades can be applied via network downloads, ensuring the PDU remains up-to-date with new features.

5. Load Indicator LED

An LED indicates overload and warning conditions based on user-defined thresholds, offering a quick visual cue to prevent circuit overloads. This feature complements the digital display, enhancing on-site monitoring capabilities.

6. Eco-Friendly Design

The AP7922B aligns with Schneider Electric’s sustainability goals, featuring packaging with at least 70% recycled cardboard (50% in some regions) and inclusion in a global take-back program for responsible disposal. Its carbon footprint is estimated at 1814 kg CO2 equivalent over its lifecycle, reflecting efforts to minimize environmental impact.

7. Robust Build and Certifications

With a durable design and certifications like CE and EN 55022, the AP7922B meets stringent safety and electromagnetic compatibility standards. Its 2U form factor saves rack space, and the 3-meter input cord provides flexible installation options.

Performance and Real-World Use

The AP7922B excels in various IT environments, including:

  • Data Centers: Managing power for servers, storage systems, and networking gear.
  • Enterprise Server Rooms: Providing remote control and monitoring for critical equipment.
  • Colocation Facilities: Ensuring secure and efficient power distribution for multi-tenant setups.

In real-world scenarios, users praise the PDU’s reliable performance and ease of integration. The ability to remotely reboot equipment saves significant time and travel costs, with one user noting, “I can restart a locked server from halfway across the world.” The digital display and LED alerts are valued for preventing overloads, and the 7360 VA capacity supports high-power devices effectively. Sequential read/write speeds for connected equipment remain unaffected, as the PDU delivers stable power distribution.

Pros and Cons

Pros

  • Individual Outlet Control: Remote on/off and reboot capabilities enhance operational efficiency.
  • Power Sequencing: Prevents inrush surges and ensures proper equipment startup.
  • Real-Time Monitoring: Digital display and LED alerts help avoid overloads.
  • Network Management: Web, SNMP, Telnet, and SSH support for remote access and integration.
  • Eco-Friendly: Recycled packaging and take-back program support sustainability.
  • Reliable Build: Durable design with robust safety certifications.
  • Warranty: 2-year repair or replace warranty for peace of mind.

Cons

  • No C19 Outlets: Limits compatibility with high-power devices requiring C19 connectors.
  • Weight: At 4.5 kg, it’s heavier than some 1U PDUs, requiring secure rack mounting.
  • Learning Curve: Advanced network features may require setup time for non-technical users.

Who Should Buy the APC AP7922B?

The AP7922B is ideal for:

  • Data Center Managers: Seeking advanced power control and monitoring for high-density racks.
  • IT Administrators: Needing remote management to minimize downtime and travel costs.
  • Small to Medium Businesses: Protecting servers and networking equipment with reliable power distribution.
  • Environmentally Conscious Users: Prioritizing sustainable products with recycling options.

If you need a PDU with C19 outlets or a lower-cost option for basic power distribution, consider APC’s Basic or Metered Rack PDU series or alternatives from brands like CyberPower.

User Feedback and Reliability

User feedback, based on sources like faithjcom.com and Amazon, highlights the AP7922B’s reliability, manageability, and security. One reviewer called it “a game-changer for remote server management,” citing the ease of rebooting equipment via the Web interface. Another appreciated the power sequencing feature for preventing breaker trips during startup. Some users, however, noted the high cost and wished for C19 outlets for broader compatibility. The PDU’s durability and integration with StruxureWare are consistently praised, with no significant reliability issues reported.

Conclusion

The APC Rack PDU, Switched, 2U, 32A, 230V, (16)C13 (AP7922B) is a powerful and versatile solution for managing power in data centers, server rooms, and IT environments. Its switched outlet control, real-time monitoring, and network management capabilities make it a top choice for professionals seeking to optimize uptime and protect equipment. While its price and lack of C19 outlets may be drawbacks, the AP7922B’s robust feature set, eco-friendly design, and reliable performance make it a valuable investment for high-demand applications. Backed by a 2-year warranty and Schneider Electric’s reputation, it delivers peace of mind for critical power management.

For more details or to purchase, CONTACT US @ TIACO TECHNOLOGIES. Verify rack compatibility and power requirements before purchasing.

Exploring the APC Rack PDU, Switched, 2U, 32A, 230V, (16)C13 (AP7922B)

The APC Rack PDU, Switched, 2U, 32A, 230V, (16)C13 (AP7922B) by Schneider Electric is a high-performance power distribution unit (PDU) designed for advanced power management in data centers, server rooms, and IT environments. Part of APC’s Switched Rack PDU series, the AP7922B offers remote outlet control, real-time monitoring, and robust power distribution, making it an essential tool for IT professionals seeking to optimize uptime and energy efficiency. In this blog, we’ll delve into the key features, specifications, benefits, and practical considerations of the AP7922B, along with insights from recent information to help you understand its value.

Key Features of the AP7922B

The AP7922B is a 2U rack-mountable PDU designed to provide advanced power control and monitoring for critical IT equipment. Here are its standout features:

  • Switched Outlets: Features 16 IEC-320 C13 outlets, each individually controllable via remote interfaces, allowing power cycling to reboot equipment or restrict unauthorized use.
  • High Power Capacity: Supports a 32A input current and 230V nominal input/output voltage, with a maximum load capacity of 7360VA, ideal for high-density environments.
  • Remote Management: Offers multiple access methods, including Web, SNMP, Telnet, SSH, and Command Line Interface, compatible with APC’s StruxureWare Data Center Expert for centralized management.
  • Power Sequencing: Enables user-defined time delays for powering up or down equipment, preventing circuit overloads during startup or shutdown.
  • Current Metering: Provides real-time remote monitoring of connected loads with user-defined alarms to warn of potential overloads, displayed via a local two-digit LED.
  • Locking IEC Receptacles: Includes locking IEC C13 outlets to secure connections and prevent accidental disconnections.
  • Environmental Monitoring: Supports a temperature/humidity sensor port for additional environmental monitoring (sensor sold separately).
  • Compact Design: Measures 3.5” (H) x 17.5” (W) x 4.5” (D) (88.9 x 444.5 x 114.3 mm) and weighs approximately 9.92 lb (4.5 kg), fitting standard 19-inch racks.

Specifications

  • PDU Type: Switched
  • Rack Height: 2U
  • Input Connection: IEC-309 32A plug with a 3.05-meter (10-foot) cord
  • Input Voltage: 230V (nominal)
  • Input Frequency: 50/60 Hz
  • Maximum Input Current: 32A per phase
  • Output Connections: 16 IEC-320 C13 outlets
  • Output Voltage: 230V
  • Load Capacity: 7360VA
  • Mount Type: Rack-mountable
  • Environmental Conditions: Operating temperature 0°C to 45°C, storage temperature -25°C to 65°C, operating elevation 0 to 3,000 meters
  • Certifications: CE, EAC for Russian Customs Union, RoHS compliant
  • Warranty: 1-year limited warranty (repair or replace)
  • Package Contents: PDU, documentation CD, installation guide, rack mounting brackets

Benefits of the AP7922B

1. Enhanced Power Control

The ability to remotely control each of the 16 C13 outlets allows IT administrators to reboot devices, manage power allocation, and restrict unauthorized access without physical intervention. This is particularly valuable for remote data centers or unmanned server rooms.

2. Prevents Overloads

Power sequencing delays ensure that equipment powers on or off in a controlled order, reducing the risk of circuit overloads. The real-time current metering and user-defined alarms further enhance safety by alerting users to potential issues before they cause downtime.

3. Seamless Integration

The AP7922B integrates with APC’s StruxureWare Data Center Expert, Operations, Capacity, and Energy Efficiency platforms, enabling centralized monitoring and management across multiple PDUs. Support for Web, SNMP, Telnet, and SSH interfaces ensures compatibility with existing IT infrastructure.

4. High Reliability

With a 7360VA load capacity and locking IEC receptacles, the AP7922B is built for high-density environments, ensuring secure connections and reliable power delivery for critical equipment like servers, networking gear, and storage systems.

5. Eco-Friendly Design

The AP7922B carries Schneider Electric’s Green Premium™ label, signifying compliance with the latest environmental regulations, transparency on environmental impacts, and a focus on low-CO2 products. This aligns with sustainability goals for modern data centers.

Recent Insights and Feedback

While specific user reviews for the AP7922B are limited in recent sources, the APC Switched Rack PDU series is praised for its reliability and advanced features. According to product descriptions, the AP7922B is part of the AP8000 series, which includes enhancements like real power monitoring and locking receptacles, addressing common pain points in data center power management. Retailers like Connection.com note fast delivery (ships in 48 hours) and emphasize the unit’s suitability for 230V environments. However, some sources, such as Voelkner.de, indicate no user reviews are available, suggesting the product may be newer or less commonly reviewed by end users.

Practical Considerations

Before purchasing the AP7922B, consider the following:

  • Compatibility: Ensure your rack environment supports a 2U PDU with IEC-309 32A input and IEC C13 output connections. Verify that your equipment operates at 230V.
  • Management Infrastructure: To fully leverage remote management, ensure your network supports Web, SNMP, Telnet, or SSH access. Integration with StruxureWare requires additional setup.
  • Environmental Monitoring: The temperature/humidity sensor is sold separately, so factor in the cost if environmental monitoring is needed.
  • Lead Time: Some retailers, like Eezee.sg, note a lead time of up to 60 working days, so plan accordingly for urgent deployments.
  • Safety and Compliance: The AP7922B is RoHS compliant and certified for use in multiple regions, but confirm local electrical standards (e.g., CE, EAC) for your area.
  • Alternatives: If individual outlet switching is not required, consider APC’s Basic or Metered Rack PDUs for lower-cost options. Use APC’s Rack PDU Selector for tailored recommendations.

Conclusion

The APC Rack PDU, Switched, 2U, 32A, 230V, (16)C13 (AP7922B) is a powerful and versatile solution for data center power management. Its remote outlet control, real-time monitoring, and high load capacity make it ideal for high-density IT environments where uptime and efficiency are critical. The unit’s integration with modern management platforms, locking receptacles, and eco-friendly design further enhance its appeal for IT professionals. While its advanced features come at a premium, the AP7922B delivers unmatched reliability and control, making it a smart investment for protecting critical equipment.

For more details, compatibility checks, or to explore APC’s full range of PDUs, CONTACT US @ TIACO TECHNOLOGIES. Power your data center with confidence using the AP7922B today!

Exploring the APC Rack PDU Switched 2U, 32A, 230V (16)C13 (AP7922B): A Comprehensive Guide

The APC Rack PDU, Switched, 2U, 32A, 230V, (16)C13 (AP7922B) by Schneider Electric is a high-performance power distribution unit (PDU) designed for data centers, server rooms, and IT environments requiring advanced power management and monitoring. This switched rack PDU provides remote control, real-time monitoring, and robust surge protection, ensuring reliable power delivery to critical equipment. In this blog, we’ll cover the key features, specifications, benefits, installation process, and maintenance tips for the AP7922B, along with insights on its applications and where to purchase it.

What is the APC AP7922B?

The APC AP7922B is a 2U rack-mountable, switched power distribution unit that delivers 230V power through 16 IEC-320 C13 outlets and a single IEC-309 32A input. Part of APC’s Switched Rack PDU series, it enables advanced power control and monitoring, allowing users to remotely manage outlets, monitor current usage, and prevent circuit overloads. With a 3.05-meter cord and compatibility with secure interfaces like Web, SNMP, Telnet, and SSH, the AP7922B is ideal for data centers, enterprise IT environments, and high-density server racks. It also integrates with APC’s StruxureWare Data Center Expert for centralized management, making it a versatile solution for modern IT infrastructure.

Key Features of the APC AP7922B

  • 16 IEC-320 C13 Outlets: Supports up to 16 devices, ideal for servers, networking equipment, and other rack-mounted hardware.
  • Remote Outlet Control: Enables power on/off functionality for individual outlets, allowing remote reboots and restricting unauthorized access.
  • Power Sequencing: User-defined time delays for powering up or down equipment, preventing circuit overloads during startup or shutdown.
  • Current Metering: Real-time monitoring of connected loads with user-defined alarms to warn of potential overloads, displayed on a two-digit LED.
  • Network Management: Accessible via secure Web, SNMP, Command Line Interface, or Telnet, with integration into APC’s StruxureWare platforms for centralized control.
  • Surge Protection: Provides reliable protection against power surges and spikes, ensuring equipment safety.
  • Locking IEC Receptacles: Prevents accidental disconnections, enhancing reliability in high-vibration environments.
  • Temperature/Humidity Sensor Port: Supports environmental monitoring for optimal data center conditions.
  • 2-Year Warranty: Backed by APC’s limited warranty for repair or replacement, ensuring long-term reliability.
  • Environmentally Friendly: Complies with RoHS and is part of APC’s recycling initiatives.

Specifications

  • PDU Type: Switched
  • Rack Height: 2U
  • Input Voltage: 200–230V
  • Input Frequency: 50/60 Hz
  • Input Connection: IEC-309 32A
  • Maximum Input Current: 32A
  • Output Voltage: 230V AC
  • Output Connections: 16 IEC-320 C13 outlets
  • Cord Length: 3.05 meters (10 feet)
  • Surge Energy Rating: Not explicitly specified, but includes robust surge protection
  • Dimensions: 88.9mm (H) x 444.5mm (W) x 114.3mm (D)
  • Weight: 4.5 kg (9.92 lbs)
  • Mount Type: Rack-mountable
  • Operating Temperature: 0–45°C
  • Operating Humidity: 0–95% (non-condensing)
  • Operating Elevation: 0–3000 meters
  • Certifications: CE, EAC, RoHS, and others (IEC 61643-11, 2014/30/EU, 2014/35/EU)
  • Warranty: 2 years
  • Package Contents: PDU, documentation CD, installation guide, rack mounting brackets

Benefits of the APC AP7922B

  1. Enhanced Power Control: Remote outlet-level control allows administrators to reboot devices, manage power cycles, and restrict access, reducing downtime and improving security.
  2. Prevent Circuit Overloads: Power sequencing and current metering help avoid overloads, ensuring stable operation of connected equipment.
  3. Real-Time Monitoring: The two-digit LED display and network interfaces provide real-time insights into power usage, enabling proactive management.
  4. Seamless Integration: Compatibility with StruxureWare Data Center Expert, Operations, Capacity, and Energy Efficiency platforms streamlines data center management.
  5. Reliable Surge Protection: Protects sensitive equipment from power surges and spikes, extending device lifespan.
  6. Flexible Installation: The 2U rack-mountable design and 3.05-meter cord allow easy integration into standard 19-inch racks.
  7. Environmental Monitoring: The temperature/humidity sensor port supports proactive management of data center conditions.
  8. Cost-Effective: Extends equipment life and reduces maintenance costs through precise power management and surge protection.

Applications

The AP7922B is suited for a variety of IT and data center environments, including:

  • Data Centers: Provides reliable power distribution and remote management for servers, storage systems, and networking equipment.
  • Enterprise IT: Supports high-density racks in corporate server rooms, ensuring uptime and equipment safety.
  • Colocation Facilities: Enables remote power control and monitoring for multi-tenant environments.
  • Edge Computing: Powers edge devices in distributed IT setups, with remote access for maintenance.
  • Telecom Installations: Manages power for telecom equipment, ensuring consistent operation.

It can also be paired with a PDU Extender (e.g., APC part 314181) for connection to large UPS systems via a terminal block, expanding its versatility.

Installation Process

Installing the APC AP7922B is straightforward with the included rack mounting brackets and documentation. Follow these steps:

  1. Unpack the Unit: Verify the package includes the PDU, documentation CD, installation guide, and rack mounting brackets.
  2. Mount the PDU: Secure the PDU to a standard 19-inch rack using the provided brackets. Ensure proper alignment and a firm connection.
  3. Connect the Input: Plug the IEC-309 32A connector into a compatible 230V power source. Ensure the circuit can handle a 32A load.
  4. Connect Devices: Attach up to 16 devices to the IEC-320 C13 outlets, ensuring secure connections with locking receptacles.
  5. Configure Network Access: Connect the PDU to the network via the Ethernet port. Access the Web, SNMP, Telnet, or SSH interface to configure outlet controls, alarms, and monitoring settings.
  6. Test Functionality: Verify the two-digit LED display shows current usage and check that remote controls function correctly. Run a test power cycle if needed.
  7. Integrate with Management Software: If using StruxureWare Data Center Expert or similar platforms, configure the PDU for centralized monitoring.

Consult the installation guide (available at www.apc.com) for detailed instructions and safety precautions.

Maintenance and Care Tips

To ensure optimal performance and longevity of the AP7922B:

  • Monitor Load Regularly: Use the current metering feature to track power usage and set alarms to prevent overloads.
  • Inspect Connections: Periodically check the IEC-309 input and C13 outlets for wear or loose connections.
  • Keep in Suitable Conditions: Operate within 0–45°C and 0–95% humidity (non-condensing). Store in a cool, dry environment when not in use.
  • Update Firmware: Check www.apc.com for firmware updates to maintain compatibility and security.
  • Clean the Unit: Use a dry cloth to remove dust from the PDU and outlets, avoiding liquids to prevent damage.
  • Recycle Responsibly: When disposing of the unit, participate in APC’s recycling program to comply with RoHS and environmental regulations.

Customer Insights

Limited customer reviews are available for the AP7922B, but feedback on similar APC Switched Rack PDUs highlights:

  • Positive Feedback: Users praise the remote management capabilities, ease of integration with StruxureWare, and reliability in data center environments.
  • Considerations: Some note the initial setup of network interfaces can be complex for non-IT professionals, requiring familiarity with SNMP or Web configurations.
  • Value: Customers appreciate the balance of advanced features and cost-effectiveness for small to medium-sized data centers.

Always check retailer reviews for the latest user experiences and verify compatibility with your setup.

Conclusion

The APC Rack PDU Switched 2U 32A 230V (16)C13 (AP7922B) is a powerful and versatile solution for data centers and IT environments, offering advanced power control, real-time monitoring, and robust surge protection. Its remote outlet management, power sequencing, and integration with StruxureWare platforms make it ideal for ensuring uptime and efficiency in critical applications. Backed by a 2-year warranty and APC’s reputation for quality, the AP7922B is a smart investment for managing power in high-density racks.

For more details or to confirm compatibility, CONTACT US @ TIACO TECHNOLOGIES. Empower your data center with the APC AP7922B today!

Powering Your Data Center: An In-Depth Look at the APC Switched Rack PDU AP7922B

In the fast-paced world of data centers and server rooms, reliable power management is critical to ensuring uptime and protecting sensitive equipment. The APC Switched Rack PDU, 2U, 32A, 230V, (16) C13 (AP7922B) by Schneider Electric is a robust, feature-rich power distribution unit (PDU) designed to provide advanced load monitoring, remote outlet control, and seamless integration into modern IT environments. This blog explores the key features, benefits, and technical specifications of the AP7922B, making it an essential component for server racks and network cabinets in the UK and beyond.

Why Choose a Switched Rack PDU?

Switched Rack PDUs go beyond basic power distribution by offering remote monitoring and individual outlet control. This allows IT administrators to manage power usage, reboot devices, and prevent overloads without physically accessing the equipment. The APC AP7922B is tailored for high-density environments, delivering reliable power distribution with advanced management capabilities for data centers, server rooms, and enterprise IT setups.

Key Features of the APC AP7922B

1. 16 IEC C13 Outlets

The AP7922B is equipped with 16 IEC-320 C13 outlets, providing ample connectivity for servers, networking equipment, and other rack-mounted devices. These outlets support a wide range of equipment, ensuring flexibility in diverse IT environments.

2. High-Capacity Power Distribution

With a 32A, 230V single-phase input via an IEC-309 32A connector and a 3-meter power cord, the AP7922B can handle a maximum input current of 32A, making it suitable for high-power applications. It delivers up to 7.4kW of power, ensuring efficient distribution to multiple devices.

3. Remote Individual Outlet Control

The AP7922B allows users to remotely turn outlets on or off, enabling power cycling to reboot locked-up equipment or disable unused outlets to prevent overloads. This feature minimizes downtime and eliminates the need for on-site visits, saving time and operational costs.

4. Power Sequencing and Delays

To prevent in-rush currents that can trip circuit breakers, the AP7922B supports power sequencing. Users can configure the order and timing of outlet activation, ensuring that equipment powers on in a controlled manner. This is particularly useful for systems where certain devices must start before others to function correctly.

5. Local and Remote Monitoring

The PDU features a built-in digital display that shows the aggregate current draw per phase, helping installers avoid overloaded circuits. Load indicator LEDs provide visual warnings when user-defined alarm thresholds are approached. Additionally, the AP7922B supports remote monitoring via Web, SNMP, Telnet, or SSH interfaces, allowing administrators to track power usage and receive alerts in real time.

6. Network Management Capabilities

The AP7922B offers full-featured network management through standards-based protocols (Web, SNMP, Telnet). This enables remote configuration, monitoring, and firmware upgrades, ensuring the PDU remains up-to-date with the latest features. It also integrates with StruxureWare Data Center Expert, providing a unified view of data center infrastructure for scalable monitoring and management.

7. Alarm Thresholds

Users can define alarm thresholds to receive network and visual alerts when power consumption nears critical levels. This proactive feature helps prevent circuit overloads and ensures continuous operation.

8. Flash Upgradeable Firmware

The AP7922B supports firmware upgrades via network download, allowing users to add new features without replacing the unit. This future-proofs the PDU, ensuring compatibility with evolving IT requirements.

9. Compact and Rack-Mountable Design

Designed for 2U horizontal installation in standard server racks, the AP7922B measures 445mm (W) x 114mm (D) x 89mm (H) and weighs approximately 9.92 lb (4.5kg). Its compact form factor optimizes rack space while supporting efficient cable management.

10. Environmental and Safety Compliance

The AP7922B is certified with CE, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, and REACH, ensuring compliance with international safety and environmental standards. It operates reliably in temperatures from 0–45°C and relative humidity of 0–95% (non-condensing). The PDU also uses packaging with at least 70% recycled cardboard, reflecting Schneider Electric’s commitment to sustainability.

Technical Specifications

Here’s a summary of the AP7922B’s key specs:

  • PDU Type: Switched, Metered
  • Rack Height: 2U
  • Input Voltage: 200–230V
  • Input Frequency: 50–60 Hz
  • Input Connector: IEC-309 32A
  • Maximum Input Current: 32A
  • Output Connectors: 16x IEC-320 C13
  • Power Capacity: Up to 7.4kW
  • Cord Length: 3.05 meters
  • Dimensions: 445mm (W) x 114mm (D) x 89mm (H)
  • Weight: 4.5kg (9.92 lb)
  • Monitoring: Current, Power, Voltage
  • Outlet Control: Lock-out, Recycle, Turn on/off
  • Certifications: CE, VDE, REACH, and more
  • Warranty: 2 years

Benefits of the APC AP7922B

  1. Enhanced Uptime: Remote outlet control and power sequencing reduce downtime by enabling quick reboots and preventing overloads.
  2. Scalable Management: Integration with StruxureWare Data Center Expert and support for SNMP/Telnet make it ideal for large-scale IT environments.
  3. Energy Efficiency: Turning off unused outlets and monitoring power usage help optimize energy consumption.
  4. Cost Savings: Remote management reduces the need for on-site maintenance, lowering operational costs.
  5. Reliability: Backed by Schneider Electric’s reputation and a 2-year warranty, the AP7922B ensures long-term performance.

Real-World Applications

The AP7922B is ideal for:

  • Data Centers: Managing power for servers, storage systems, and networking equipment.
  • Enterprise IT: Supporting high-density racks in corporate server rooms.
  • Colocation Facilities: Providing tenants with precise control over power distribution.
  • Edge Computing: Powering compact IT setups in remote or branch offices.

Customer Feedback

Users appreciate the AP7922B for its robust remote management features and reliable performance in high-demand environments. Some have noted the initial setup of network configurations can be complex, but the intuitive web interface and documentation simplify the process. The ability to remotely reboot devices and monitor power usage is frequently cited as a game-changer for IT administrators.

Conclusion

The APC Switched Rack PDU AP7922B is a powerful and versatile solution for modern data centers and IT environments. Its combination of remote outlet control, power sequencing, real-time monitoring, and seamless integration with management platforms makes it a top choice for IT professionals seeking reliability and efficiency. Whether you’re managing a small server rack or a large data center, the AP7922B delivers the performance and flexibility needed to keep your equipment powered and protected.

For more details or to purchase, CONTACT US @ TIACO TECHNOLOGIES.

Understanding the APC AP7922B Rack PDU: A Comprehensive Guide to Switched Power Distribution

In the fast-paced world of data centers and IT infrastructure, efficient power management is critical to ensuring uptime, optimizing performance, and maintaining operational stability. The APC AP7922B Rack PDU, Switched, 2U, 32A, 230V, (16)C13 is a robust and versatile power distribution unit (PDU) designed to meet the demands of modern server rooms and network cabinets. This blog explores the features, benefits, and applications of the AP7922B, providing insights for IT professionals, data center managers, and businesses looking to enhance their power management solutions.

What is the APC AP7922B Rack PDU?

The APC AP7922B is a 2U, switched rack-mounted power distribution unit manufactured by Schneider Electric. It delivers reliable power distribution with advanced remote management capabilities, making it an ideal choice for high-density server environments. With a 32A input at 230V and 16 IEC-320 C13 outlets, this PDU is designed to power multiple devices while offering precise control and monitoring to prevent overloads and ensure operational efficiency.

Key Specifications

  • Form Factor: 2U, horizontal rack-mountable
  • Input: IEC-309 32A, 230V, single-phase, 3-meter lead
  • Output: 16 IEC-320 C13 outlets
  • Dimensions: 445 x 114 x 89 mm
  • Maximum Current: 32A
  • Input Voltage: 200-230V
  • Frequency: 50-60 Hz
  • Certifications: CE, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, REACH
  • Monitoring: Current, power, voltage
  • Outlet Control: Lock-out, recycle, turn off, turn on
  • Network Management: Web, SNMP, Telnet, SSH, and InfraStruXure Manager interfaces

Key Features of the APC AP7922B

1. Remote Management Capabilities

The AP7922B offers full-featured network management through standards-based interfaces such as Web, SNMP, Telnet, and SSH. Administrators can remotely monitor and control individual outlets, enabling power cycling of locked-up equipment, turning off unused outlets to prevent overloads, and managing power distribution from anywhere on the network. This minimizes downtime and eliminates the need for on-site interventions, saving time and operational costs.

2. Power Delays for Controlled Sequencing

The PDU allows users to configure the sequence in which outlets are powered on or off. This feature, known as power delays, prevents in-rush currents during startup, which can overload circuits and cause equipment failure. It also enables administrators to prioritize power delivery to critical devices, ensuring dependent equipment functions properly.

3. Local Current Monitoring Display

A built-in digital display shows the aggregate current draw per PDU, providing real-time visibility into power usage. This helps installers and administrators avoid overloading circuits by issuing visible warnings when the current approaches the maximum amperage limit.

4. Load Indicator LED and Alarm Thresholds

The AP7922B includes a load indicator LED that alerts users to overload or warning conditions based on user-defined thresholds. Network and visual alarms further enhance monitoring by notifying administrators of potential issues, ensuring proactive management of power loads.

5. Flash Upgradeable Firmware

The PDU supports firmware upgrades via network download, allowing users to incorporate future enhancements without replacing the unit. This ensures the AP7922B remains compatible with evolving data center requirements.

6. Integration with StruxureWare Data Center Expert

The AP7922B integrates seamlessly with Schneider Electric’s StruxureWare Data Center Expert, a scalable monitoring system that collects and distributes critical alerts, surveillance video, and key infrastructure data. This provides a unified view of complex environments, enhancing data center management.

7. Security Features

To ensure secure remote management, the AP7922B includes user login access, password protection, and network protocol security, safeguarding against unauthorized access.

Benefits of the APC AP7922B

Enhanced Power Management

The ability to monitor and control individual outlets remotely allows for precise power management, reducing the risk of overloads and optimizing energy efficiency. Administrators can recycle power to resolve equipment issues without physical access, minimizing downtime.

Scalability and Flexibility

With 16 C13 outlets and a single 32A input, the AP7922B supports a wide range of rack-mounted equipment, from servers to networking devices. Its 2U form factor fits standard racks, making it adaptable to various data center configurations.

Cost and Time Savings

By using a single branch whip to power multiple devices, the AP7922B simplifies installation and reduces cabling costs. Remote management capabilities further save time by eliminating the need for on-site visits.

Reliability and Durability

Backed by Schneider Electric’s reputation for quality, the AP7922B is built for durability and comes with a 12-month warranty (excluding software). Its certifications ensure compliance with international standards, making it a reliable choice for critical IT environments.

Applications of the AP7922B

The APC AP7922B is ideal for:

  • Data Centers: Provides reliable power distribution and monitoring for high-density server racks.
  • Network Cabinets: Supports networking equipment with precise control and remote management.
  • Enterprise IT: Ensures uptime for critical systems through advanced load monitoring and power sequencing.
  • Colocation Facilities: Enables efficient power management for multi-tenant environments.

Why Choose the APC AP7922B?

The APC AP7922B stands out for its combination of advanced features, robust build, and integration capabilities. Its remote management, power sequencing, and real-time monitoring make it a powerful tool for maintaining operational efficiency in demanding IT environments. Whether you’re managing a small server room or a large data center, this PDU delivers the reliability and control needed to keep your systems running smoothly.

Conclusion

The APC AP7922B Rack PDU Switched 2U 32A 230V (16)C13 is a high-performance solution for modern power management needs. Its advanced features, such as remote outlet control, power sequencing, and real-time monitoring, make it an essential component for data centers and IT infrastructures. By choosing the AP7922B, businesses can enhance operational efficiency, reduce downtime, and ensure reliable power delivery to critical equipment.