Balanced Capacity, Maximum Efficiency: The Vertiv ITC301A0101A00A

Between smaller edge deployments and full-scale data center infrastructure sits a genuinely important capacity tier — facilities large enough to need real three-phase protection, but not yet at the scale of a massive centralized UPS system. The Vertiv Liebert EXS ITC301A0101A00A occupies that space precisely, delivering 30kVA of double-conversion protection in the same compact, transformer-free design that defines the EXS line.

What the Vertiv ITC301A0101A00A Delivers

Liebert EXS combines compact design and improved performances. It is able to provide the utmost active power possible in a compact footprint. In fact, its improved design reduces its footprint to a minimum and enhances its double conversion efficiency up to 96.2%, providing continuous power protection with optimised internal runtime in a standalone solution. At 30kVA, the ITC301A0101A00A delivers substantial three-phase capacity for data centers, server rooms, and commercial facilities that need genuinely serious power protection without committing to a much larger, higher-cost system.

Efficiency Behind the Vertiv ITC301A0101A00A

Double conversion efficiency reaches up to 96.2%, with ECO mode efficiency climbing as high as 99% — figures that translate directly into real operating savings over the life of the unit. The unit also maintains a unity output power factor, meaning nearly all of its rated 30kVA capacity is delivered as genuinely usable output power, rather than headroom you’re paying for but can’t actually draw on.

A 0-Minute Autonomy Configuration

This particular ITC301A0101A00A configuration ships with 0 minutes of integrated battery autonomy — purpose-built for facilities that already have an external battery cabinet, dedicated DC power infrastructure, or generator backup in place. Rather than duplicating existing runtime infrastructure, this configuration lets you architect your facility’s power protection strategy exactly the way it actually needs to be built, without paying for internal battery capacity that goes unused.

Reduced Total Cost of Ownership

The Liebert EXS platform is built around a comprehensive set of cost- and space-saving engineering principles: reduced total cost of ownership, a compact footprint, multiple internal runtime configurations, high power density, installation flexibility, integrated maintenance bypass, and integrated input and output power distribution. Dual mains input is also included, giving the unit genuine redundancy by allowing it to draw from two separate power sources.

Integrated Maintenance Bypass

Critical infrastructure still needs periodic servicing, and the ITC301A0101A00A is engineered so that maintenance never introduces downtime. Its integrated maintenance bypass ensures connected critical loads keep operating even during scheduled service work — a genuinely important safeguard for facilities where any interruption, planned or otherwise, carries real operational cost.

Parallel Capability for Scaling Beyond a Single Unit

The Vertiv ITC301A0101A00A isn’t a fixed capacity ceiling. Liebert EXS can be connected with up to four units in parallel, and a single unit can be upgraded to parallel operation via easy to modify software settings — a genuine, cost-effective path to expanding total capacity or adding real redundancy as an organization’s infrastructure needs grow, without requiring a complete system replacement.

Flexible Battery and Installation Architecture

Common or distributed battery bank configurations, along with internal and external battery options, give facilities teams real flexibility in how they build out their overall runtime and redundancy strategy around the unit. Combined with genuinely flexible installation, the ITC301A0101A00A adapts to a wide range of data center and enterprise environment layouts rather than forcing a single rigid deployment approach.

Backed by Global Vertiv Support

Vertiv offers a complete range of services specifically designed for three-phase UPS systems, with coverage options extending up to 5 years and backed by a global service network spanning more than 270 service centers and 2,700 field engineers in over 130 countries — genuine, dependable support behind a UPS playing a central role in your facility’s power protection strategy.

The Bottom Line on the Vertiv ITC301A0101A00A

For data centers, server rooms, and commercial facilities that need genuine 30kVA three-phase, double-conversion protection without stepping up to a much larger system, the Vertiv Liebert EXS ITC301A0101A00A delivers real efficiency up to 96.2%, integrated maintenance bypass, dual mains input, and parallel scalability up to four units — all in a 0-minute autonomy configuration built for facilities with their battery and generator architecture already in place. It’s compact, high-efficiency power protection sized precisely for the businesses that need serious continuity without unnecessary overbuild.