Sale!

Liebert MPT 10kva 3/3 or 3/1 0mins Autonomy

15,000,000.00 14,600,000.00

The new Vertiv™ Liebert® MTP is a monolithic transformer-free UPS, which delivers full active power by providing exceptional power availability to mission-critical applications. The internal Innovative design reduces its footprint to a minimum, providing continuous power protection with optimised internal runtime in a standalone solution, making the Liebert MTP perfect for IT applications. Liebert MTP can achieve a remarkable efficiency level of up to 95.5% in proper online double conversion mode. Liebert MTP can further increase efficiency up to 98.5% by operating in ECO mode. The Liebert MTP makes your mission-critical space a peaceful place through its enhanced event analysis, voice notifications for alarms, and an intelligent colored multi-language touch screen LCD display. The architecture of Liebert MTP makes it exceptionally easy to install, connect, operate, maintain, and service, making it ideal for a wide range of small and medium business applications. Liebert MTP also comes equipped with casters to facilitate ease of movement and relocation. Furthermore, Liebert MTP features multiple communication ports including dry contacts, SNMP, and Modbus which enables remote monitoring of the UPS system.

Description

Technical Specifications Nominal Rating (kVA/kW) 10-15-20 30-40 60 80 100-120 160-200

Input Nominal Input Voltage (V) 380/400/415 VAC 3-Phase, 4 Wire Input Voltage Range (V) 110 to 300 VAC @ 50% load; 184 to 276 VAC @ 100% load For 60-100-120-160-200kVA: 305 ~ 478; 208 ~ 304 (output derated below 70%) Nominal Input Frequency (Hz) 50/60 Input Frequency Range (Hz) 40-70 For 60-100-120-160-200kVA: 46Hz ~ 54 Hz @ 50Hz system 56Hz ~ 64 Hz @ 60Hz system Input Power Factor (kW/kVA)* 0.99 Current THD at full linear load (THDi%)* <4

Battery With Internal Batteries Battery Type 12 V, 9 AH 12 V, 9 AH Not Available No of Battery Blocks 32 Without Internal Batteries Battery Type VRLA Charging Current (Max.) 1 to 12 A (Adjustable) 1 to 18 A (Adjustable) 2 to 32 A (Adjustable) 36 A (Adjustable) 54 A (Adjustable) No of Battery Blocks 32-40

Output Nominal Output Voltage (V) 380/400/415 VAC (3-Phase) Nominal Output Frequency (Hz) 50/60 Maximum Active Power (kW) 10-15-20 30-40 60 80 100-120 160-200 Voltage Harmonic Distortion (%) <2% for Linear loads <5% for Non-linear loads <2% for linear loads <4% for non-linear loads <1% for linear loads <5% for non-linear loads <2% for linear loads <4% for non-linear loads Overload Capacity at 25 °C 100% ~ 110%, 60 min; 111% ~ 125%, 10 min; 126% ~ 150%, 1 min; >150%, 200 ms

Efficiency Double Conversion Mode* Up to 95.5% ECO Mode Up to 98.5%

Dimensions and Weight With Internal Batteries Dimensions (D x W x H) in mm 626 x 250 x 826 780 x 300 x 1000 Not Available Weight (kg) 139 250 Without Internal Batteries Dimensions (D x W x H) in mm 626 x 250 x 826 780 x 300 x 1000 1000 x 320 x 800 790 x 360 x 1010 1000 x 430 x 1200 1000 x 600 x 1200 Weight (kg) 43 67 89 113 200 265

General Nosie at 1 m (dBA)* <62 <70 <75 <75 <75 Operating Temperature (°C) 0 ~ 40 Relative Humidity (%RH) 0 to 95, non-condensing Altitude (m) 0 to 1000 without derating Protection level IEC (60529) IP20 General and safety requirements for UPS IEC/EN 62040-1 EMC requirements for UPS IEC/EN 62040-2, Category C3